    GIT Series GIS High Voltage Test Set hits:

    Product Description

    GIT Series GIS High Voltage Test Sets integrate the high voltage boosting, high voltage measurement, high voltage transformer, high voltage coupling capacitors and all components in a sealed space. High voltage generated with two modes: using reactor inductance and test object capacitance to realize voltage resonance test, to obtain a high voltage, high current from test object. The other one is to obtain required high voltage directly from high voltage transformer.


    It is widely used for high voltage, big capacity GIS power equipment insulated withstand voltage test, partial discharge test and GIS transformer accuracy test, suitable for GIS substation, GIS power equipment manufacturer, basin type electrical insulator manufacturer.

    Features

    • The High voltage obtained are well sealed and shielded in containers, protect the safety of person, no outside interference;
    • Accurate test measurement;
    • If adding a high voltage sleeve interface,it can lead to high voltage,that can do various high voltage test to traditional high voltage equipment;
    • The safest type of high voltage test.

    Specifications

    • Voltage grade : 100kV, 200kV, 250kV, 300kV, 500kV, 750kV, 1000kV ;
    • Capacity : 50-2000kVA ;
    • High voltage generated mode: high voltage transformer voltage boost and series resonance(power frequency,frequency conversion);
    • All methods of boost voltage are one level voltage boost,no need to cascade boost voltage;
    • Input voltage: 0.35-10kV;
    • partial discharge capacity: Rated voltage 3pc (normal environment) ;
    • Impedance voltage: 5%;
    • Temperature rise: no more than 65k (50Hz) when rated current operates 60mins.

    Accessories

    • Basic Accessories: High-voltage generator, High voltage coupling capacitors, High voltage divider, The console and Low-voltage compensation reactor, Partial discharge tester, Inverter power.
    • Optional Accessories: High voltage transformers, Three phase test switch and insulator interfaces of docking basin different manufacturers.

    CONTACT US
    Address: F/10, Block B7, JinYinTan Modern Enterprise City, Dongxihu District, Wuhan, China
    Email: info@hvhipot.com
    Skype: hvhipot@hotmail.com
    Tel: +86-27-85568138
    Fax: +86-27-65606183
    NAVIGATION
  • Company

    Company

  • Product

  • News

  • Services

  • Contact us

  • русский

  • All Rights Reserved Copyright@HV Hipot Electric Co.,Ltd.