GDTL series AC Resonant Test System for Generators can be used by adjusting inductance of the reactor, or adjusting the work way of resonant frequency of the system to achieve resonance. You can also use both two methods to achieve resonance. In the voltage boosting process, if the resonant point deviate, you can find it exactly by the way of fine tuning frequency, which ensure a high Q value and reduce power capacity and volume weight of test equipment.
GDTF- 100 / 50 | |
Input voltage (V) | 380 |
Output voltage (kV) | 0- 50 |
Capacity (kVA) | 100 |
Application scope | Generator--capacitance to the ground 0.07-0.13 μF |
10 kV (300 mm² ) cable ≤ 1 km | |
Main configurations | 50kV/1A Fixed reactor 1 set |
50kV/1A Adjustable reactor 1 set | |
Capacitive divider 50kV | |
GDTF-150/50 | |
Input voltage (V) | 380 |
Output voltage (kV) | 0- 50 |
Capacity (kVA) | 150 |
Application scope | Generator--capacitance to the ground 0.13-0.2 μF |
10 kV (300 mm² ) cable ≤ 1.5 km | |
Main configurations | 50kV/1.5A Fixed reactor 1 set |
50kV/1.5A Adjustable reactor 1 set | |
Capacitive divider 50 kV | |
GDTF- 225/50 | |
Input voltage (V) | 380 |
Output voltage (kV) | 0- 50 |
Capacity (kVA) | 225 |
Application scope | Generator--capacitance to the ground 0.2-0.27 μF |
10 kV (300 mm ² ) cable ≤ 2.5 km | |
Main configurations | 50kV/1.5A Fixed reactor 2 sets |
50kV/1.5A Adjustable reactor 1 set | |
Capacitive divider 50 kV | |
GDTF- 360/60 | |
Input voltage (V) | 380 |
Output voltage (kV) | 0- 60 |
Capacity (kVA) | 360 |
Application scope | Generator--capacitance to the ground 0.27-0.33 μF |
Main configurations | 60kV/2A Fixed reactor 1 set |
60kV/2A Adjustable reactor 1 set | |
Capacitive divider 60kV |
GDTF (L) - 540/60 | |
Input voltage (V) | 380 |
Output voltage (kV) | 0-60 |
Capacity (kVA) | 540 |
Application scope | Generator--capacitance to the ground 0.1-0.7 μF |
Main configurations | 60kV/3A Fixed reactor 2 se ts |
60kV/3A Adjustable reactor 1 set | |
Capacitive divider 60 kV | |
GDTF (L) - 1080/60 | |
Input voltage (V) | 380 |
Output voltage (kV) | 0-60 |
Capacity (kVA) | 1080 |
Application scope | Generator--capacitance to the ground 0.3-1.5 μF |
Main configurations | 60kV/4.5A Fixed reactor 2 sets |
60kV/4.5A Adjustable reactor 2 sets | |
Capacitive divider 60kV | |
GDTF (L) - 2160/60 | |
Input voltage (V) | 380 |
Output voltage (kV) | 0-60 |
Capacity (kVA) | 2160 |
Application scope | Generator--capacitance to the ground 0.5-2.5 μF |
Main configurations | 60kV/9A Fixed reactor 2 sets |
60kV/9A Adjustable reactor 2 sets | |
Capacitive divider 60kV |