Tel: +86-27-85568138
AC Resonant Test System For Substation Electrical Equipment, Is Mainly Composed Of Variable Frequency Power,Exciting Transformers,Reactors, Capacitive Dividers, Which Designed For AC Withstand Voltage Test Of Substation Electric Primary Equipment 220kV Or Below.
Applications
GDTF-108/108 | |
Input voltage (V) | 380 |
Output voltage (kV) | 0-108 |
Capacity (kVA) | 108 |
Application scope | 31500kVA or below |
35kV power transformer | |
35kV circuit breaker and bus bar,insulators | |
10kV (300 mm²) cable 2000m | |
35k V(300 mm²)cable 500m | |
Main configurations | 5kW Variable frequency source 1 set |
5kVA Exciting transformer 1 set | |
Reactors 27kV/1A 4sets | |
Capacitive divider 100kV | |
GDTF-216/216 | |
Input voltage (V) | 380 |
Output voltage (kV) | 0-216 |
Capacity (kVA) | 216 |
Application scope | 110kV Circuit breaker and bus bar |
110kV GIS | |
35kV(300 mm²) cable 1500m | |
10kV(300 mm²) cable 3km | |
110kV full insulation Transformer | |
Main configurations | 10kW Variable frequency source 1 set |
10kVA Exciting transformer 1 set | |
Reactors 54kV/1A 4sets | |
Capacitive divider 200kV | |
GDTF-270/270 | |
Input voltage (V) | 380 |
Output voltage (kV) | 0-270 |
Capacity (kVA) | 270 |
Application scope | 110kV GIS and transformer |
110kV GIS and transformer | |
35kV (300 mm²) cable 2km | |
Main configurations | 15kW Variable frequency source 1 set |
15kVA Exciting transformer 1 set | |
Reactors 54kV/1A 5sets | |
Capacitive divider 300kV | |
GDTF-200/400 | |
Input voltage (V) | 380 |
Output voltage (kV) | 0-400 |
Capacity (kVA) | 200 |
Application scope | 220kV GIS and transformer |
110kV GIS and transformer | |
Main configurations | 10kW Variable frequency source 1 set |
10kVA Exciting transformer 1 set | |
Reactors 100kV/0.5A 4sets |
|
Capacitive divider 400kV | |
GDTF-400/400 | |
Input voltage (V) | 380 |
Output voltage (kV) | 0-400 |
Capacity (kVA) | 400 |
Application scope | 220kV GIS and transformer |
10kV (300 mm²) cable 4km | |
35kV (300 mm²) cable 1km | |
Main configurations | 20kW Variable frequency source 1 set |
20kVA Exciting transformer 1 set | |
Reactor 100kV/ 1 A 4sets |
|
Capacitive divider 400kV | |
GDTF-520/260 | |
Input voltage (V) | 380 |
Output voltage (kV) | 0-260 |
Capacity (kVA) | 520 |
Application scope | 110KV Circuit breaker and bus bar |
110kV GIS | |
110kV (300 mm²) cable 800m | |
35kv (300 mm²) cable 3km | |
10kV (300 mm²) cable 6km | |
110kv full insulation Transformer | |
Main configurations | 25kW Variable frequency source 1 set |
25kVA Exciting transformer 1 set | |
Reactor 65kV/2A 4sets | |
Capacitive divider 300kV | |
GDTF-500/500 | |
Input voltage (V) | 380 |
Output voltage (kV) | 0-500 |
Capacity (kVA) | 500 |
Application scope | 220kV or below CT/PT |
220kV or below bushing | |
220kV or below Insulators, disconnectors | |
220kV or below Circuit breaker | |
220kV or below Insulation Instrument | |
Main configurations | 20kW Variable frequency source 1 set |
20kVA Exciting transformer 1 set | |
Reactor 125kV/1A 4sets | |
Capacitive divider 500kV | |
GDTF-600/600 | |
Input voltage (V) | 380 |
Output voltage (kV) | 0-600 |
Capacity (kVA) | 600 |
Application scope | 110kV (300 mm²) cable 800m |
35kv (300 mm²) cable 110m | |
35-220kV GIS ,transformers, insulators | |
Main configurations | 30kW Variable frequency source 1 set |
30kVA Exciting transformer 1 set | |
Reactor 120kV/1A 5sets | |
Capacitive divider 600kV | |
GDTF-800/800 | |
Input voltage (V) | 380 |
Output voltage (kV) | 0-800 |
Capacity (kVA) | 800 |
Application scope | 110kV (300 mm²) cable 800m |
220kv (300 mm²) cable 500m | |
35-500kV GIS ,transformers,insulators | |
Main configurations | 40kW Variable frequency source 1 set |
40kVA Exciting transformer 1 set | |
Reactor 200kV/1A 4sets | |
Capacitive divider 800kV |