GDTF Series AC Resonant Test System For Cables Are Composed Of Frequency/Voltage Adjustment Power,Exciting Transformers, Reactors, Capacitive Divider.The Power Frequency Can Be Adjustable,Which Make The Reactor And Tested Capacitor Resonance.
GDTF-44/22 | |
Input voltage (V) | 380 |
Output voltage (kV) | 0-22 |
Capacity (kVA) | 44 |
Application scope | 10kV cable ≤ 1km(300 mm² ) |
Main configurations | 2.5kW Variable frequency source 1 se t |
2.5kVA Exciting transformer 1 set | |
Reactors 22kV/1A 2 sets | |
Capacitive divider 25 kV | |
GDTF-88/22 | |
Input voltage (V) | 380 |
Output voltage (kV) | 0-22 |
Capacity (kVA) | 88 |
Application scope | 10kV cable ≤ 2km(300 mm² ) |
Main configurations | 4kW Variable frequency source 1 set |
4kVA Exciting transformer 1 set | |
Reactors 22kV/2A 4sets | |
Capacitive divider 25 kV | |
GDTF-132/22 | |
Input voltage (V) | 380 |
Output voltage (kV) | 0-60 |
Capacity (kVA) | 132 |
Application scope | 10kV (300 mm² ) cable 3km |
35kV (300 mm² ) cable 1km | |
Main configurations | 6kW Variable frequency source 1 set |
6kVA Exciting transformer 1 set | |
Reactors 22kV/2A 3 sets | |
Capacitive divider 60kV | |
GDTF- 176/22 | |
Input voltage (V) | 380 |
Output voltage (kV) | 0-60 |
Capacity (kVA) | 176 |
Application scope | 10kV (300 mm² ) cable 4km |
35kV (300 mm² ) cable 1km | |
Main configurations | 7.5 kW Variable frequency source 1 set |
7.5 kVA Exciting transformer 1 set | |
Reactors 22kV/2A 4sets | |
Capacitive divider 60kV | |
GDTF-264/22 | |
Input voltage (V) | 380 |
Output voltage (kV) | 0-60 |
Capacity (kVA) | 264 |
Application scope | 10kV (300 mm² ) cable 6km |
35kV (300 mm² ) cable 2km | |
Main configurations | 10kW Variable frequency source 1 set |
10kVA Exciting transformer 1 set | |
Reactor 22kV/2A 6 sets | |
Capacitive divider 60kV | |
GDTF-330/22 | |
Input voltage (V) | 380 |
Output voltage (kV) | 0-60 |
Capacity (kVA) | 330 |
Application scope | 10kV (300 mm² ) cable 8 km |
35kV (300 mm² ) cable 2.5 km | |
10-35kV switchgear, transformers | |
Main configurations | 15kW Variable frequency source 1 set |
15kVA Exciting transformer 1 set | |
Reactor 22kV/2.5A 6 sets | |
Capacitive divider 60kV | |
GDTF-640/32 | |
Input voltage (V) | 380 |
Output voltage (kV) | 0-130 |
Capacity (kVA) | 640 |
Application scope | 10kV (300 mm² ) cable 10 km |
35kV (300 mm² ) cable 4 km | |
110kV cable ≤ 1km(400 mm² ) | |
35-110kV GIS | |
Main configurations | 25 kW Variable frequency source 1 set |
25 kVA Exciting transformer 1 set | |
Reactor 32 kV/2.5A 8 sets | |
Capacitive divider 130kV | |
GDTF-1280/ 32 | |
Input voltage (V) | 380 |
Output voltage (kV) | 0-130 |
Capacity (kVA) | 1280 |
Application scope | 10kV (300 mm² ) cable 20 km |
35kv (300 mm² ) cable 8km | |
110kV cable ≤ 2km(400 mm ² ) | |
35- 110kV GIS | |
Main configurations | 50kW Variable frequency source 1 set |
50kVA Exciting transformer 1 set | |
Reactor 32kV/5A 8 sets | |
Capacitive divider 130kV | |
GDTF-1950/130 | |
Input voltage (V) | 380 |
Output voltage (kV) | 0-520 |
Capacity (kVA) | 1950 |
Application scope | 110kV cable ≤ 2.5km |
220kv GIS | |
110kV switchgear,transformers | |
Main configurations | 100kW Variable frequency source 1 set |
100kVA Exciting transformer 1 set | |
Reactor 130kV/3.75A 4sets | |
Capacitive divider 520kV | |
GDTF-3250/130 | |
Input voltage (V) | 380 |
Output voltage (kV) | 0-520 |
Capacity (kVA) | 3250 |
Application scope | 110kV cable ≤ 5km |
110kV/220kV switchgear | |
GIS,transformers | |
Main configurations | 150kW Variable frequency source 1 set |
150kVA Exciting transformer 1 set | |
Reactor 130kV/6.25A 4sets | |
Capacitive divider 520kV | |
GDTF-650 0/130 | |
Input voltage (V) | 380 |
Output voltage (kV) | 0- 520 |
Capacity (kVA) | 6500 |
Application scope | 110kV cable ≤ 10km |
110kV/220kV switchgear | |
GIS,transformers | |
Main configurations | 300kW Variable frequency source 1 set |
300kVA Exciting transformer 1 set | |
Reactor 130kV/ 12.5A 4sets | |
Capacitive divider 520kV |