The 110kV safety equipment testing laboratory project has been successfully delivered and put into operation in Guangxi.

The 110kV safety equipment testing laboratory project has been successfully delivered and put into operation in Guangxi.

Recently, the 110kV intelligent safety equipment testing laboratory tailored by HV HIPOT Electric co. LTD  for a power company in Guangxi was successfully delivered. The complete set of independently developed equipment was installed, debugged and passed the acceptance inspection. All performance indicators exceeded the national grid standard Q/GDW 12154—2021, and was officially put into operation, effectively building a digital safety barrier for the on-site operations of the local power grid.

1F4A9106_副本

1F4A9384_副本
This laboratory has established a three-dimensional comprehensive detection system integrating “electrical testing + mechanical performance + parameter measurement”. It can complete the preventive and acceptance tests for all commonly used safety tools of 110kV and below in one step, effectively addressing the industry pain points such as the scattered nature of traditional detection processes, low efficiency, large human errors, and untraceable data.

1F4A9155 拷贝_副本
The core equipment are all star products independently developed by  HV HIPOT . They have outstanding technical advantages:
GDJS-8A Circulating Water Injection Insulation Boot and Glove Leakage Current Testing Station: It adopts closed-loop circulating water technology, automatically drains water without residue, supports 8-position synchronous and parallel testing, automatically collects leakage current and intelligently rejects defective products, and has built-in dual safety protection against overvoltage and overcurrent;
GDJ-150D Electric Insulation Rod Withstand Voltage Test Electrode Device: It enables precise withstand voltage testing of 110kV insulation rods, with independent monitoring for each section, real-time output of high-precision data, and avoidance of resource waste caused by the entire rod being scrapped;
GDYT-20N Safety Belt Static Load Testing Machine + GDXZ-1000N Ladder Tension Strength Testing Machine: Equipped with high-precision sensors, with loading accuracy of ±1%, test data is automatically stored, and the entire process is traceable, meeting industry compliance audit requirements;
GDY Insulation Pad Testing Platform: Precisely tests the insulation strength and withstand voltage performance of insulation pads, covering all the detection requirements for common protective tools used in distribution rooms.
1F4A9120 拷贝_副本

1F4A9187_副本
The entire system operates in a fully automated manner throughout the process. At the acceptance site, the customers highly praised: “This equipment has a high degree of automation, with precise and reliable data, and significantly reduces the safety risks of manual operations.” As an industry leader with over 20 years of experience in high-voltage testing,  HV HIPOT  will continue to empower power safety with technological innovation and create more intelligent and efficient detection solutions.


Post time: Jun-05-2026

Send your message to us:

Write your message here and send it to us