Partial Discharge Measurement Device

  • GDYT-150kW  PD-free Induced Voltage Test System

    GDYT-150kW PD-free Induced Voltage Test System

    This partial-discharge-free induced withstand voltage test system is designed for testing power transformers with rated capacities of 3,000kVA to 5,000kVA and rated voltages of 34.5 kV or below. Utilizing a high-precision, low-interference partial discharge detection system, it accurately reflects the transformer’s insulation condition, providing a reliable basis for factory acceptance tests, handover tests, and preventive maintenance, ultimately ensuring the safe, stable, and long-term operation of the power equipment.

  • GDUI-511PD Acoustic PD Camera | Handheld Acoustic Imager for Partial Discharge & Gas Leak Detection

    GDUI-511PD Acoustic PD Camera | Handheld Acoustic Imager for Partial Discharge & Gas Leak Detection

    GDUI-511PD Acoustic PD Camera, using high sensitivity digital microphone array, is mainly used to detect the leakage of pressurized gas and partial discharge of electrical insulation equipment, and can be extended to detect infrared thermal imaging, internal leakage or other detection functions.

    It features built-in flash lights for low-light detection and supports external sensor integration. The aluminum alloy casing enhances durability, while the explosion-proof design meets structural and circuit requirements. Some models are certified for explosion-proof environments (ensure your purchase is explosion-proof certified).

  • GDYT-10kW PD-Free Induced Voltage Test System | 10kW/100kV Variable Frequency Partial Discharge Test Set

    GDYT-10kW PD-Free Induced Voltage Test System | 10kW/100kV Variable Frequency Partial Discharge Test Set

    GDYT-10kW PD free induced voltage test set is variable frequency AC power supply (hereinafter called VF power supply). It inputs single AC voltage and frequency, after inversion, it generates stable and pure sine wave.

    The equipment uses PWM (Pulse Width Modulation) technology to make the device small size, light weight and highly efficient. Digital signal processing technology provides high-precision and high-speed measurement functions such as voltage, frequency, current, apparent power, and power factor. Meanwhile, it use high-power IGBT module design to reduce circuit complexity, improve product stability, reduce power consumption, and increase the capacity of a single unit, plus a number of ultra-isolation transformers to completely isolate the mains and the load to increase the functions, which can ensure the accuracy.

  • GIT-450kVA/150kV PD-free AC Dielectric Test Set

    GIT-450kVA/150kV PD-free AC Dielectric Test Set

    The GIT-450kVA/150kV PD-free AC Dielectric Test Set is an advanced automatic withstand voltage tester designed in accordance with the latest national power industry standards. It utilizes PLC controller technology, 2.4G ISM networking, and an advanced human-machine interface. This test equipment is suitable for power frequency withstand voltage testing and partial discharge testing of high-voltage electrical equipment of 150kV and below.The max. capacitance of tested object is 0.05μF at 150kV.

  • GDYT-10/100  Partial Discharge Testing System 10kVA/100kV

    GDYT-10/100 Partial Discharge Testing System 10kVA/100kV

    This set of equipment is mainly used for partial discharge measurement and other scientific experimental research.

  • GDPD-PTU PD Online Monitoring System for Oil Transformer

    GDPD-PTU PD Online Monitoring System for Oil Transformer

    The aging and damage of the internal insulation of the transformer mostly starts from local discharge. The reason for local discharge is that the electric field is too concentrated at a certain point, or the electric field strength at a certain point is too large. At present, the main methods for detecting transformer local discharge faults are: UHF ultra-high frequency monitoring method, HFCT high-frequency pulse current local discharge measurement method (pulse current method), ultrasonic local discharge measurement method (ultrasonic method), and oil gas chromatography analysis method.

  • GDUVI-41  UV Imager

    GDUVI-41 UV Imager

    GDUVI-41 UV imager adopts ergonomic design and key operation, which is very suitable for daily maintenance of various high-voltage electrical equipment. The instrument adopts solar-blind technology to simultaneously image the visible light and ultraviolet light paths, and realizes the location of the ultraviolet light-emitting position through the real-time synchronous fusion of the two images, which can be detected around the clock. The video display can display the ultraviolet video and the visible light video separately, or the superimposed composite video, which can count the ultraviolet light spots in the selected range and provide the measurement data.

  • GDJF-2006S  Partial Discharge Detector

    GDJF-2006S Partial Discharge Detector

    GDJF-2006S Digital Partial Discharge Detector is widely used for detecting partial discharge of high voltage equipment such as power transformers, instrument transformer, HV circuit breaker, GIS, Zinc oxide surge arrester, power cable. It also can make type tests and monitor insulation operation.

    GDJF-2006S includes main unit, PD software, current transformer, input unit, calibration pulse generator, input adapter, antenna amplifier and connection cable etc.

  • GDPD-316M Handheld Partial Discharge Detector

    GDPD-316M Handheld Partial Discharge Detector

    The GDPD-316M handheld Partial Discharge Detector uses smart quick intelligent power test system (Soft No. 1010215, trademark registration number 14684781). It can flexibly configure various sensors according to different products to be tested. TEV, ultrasonic and HFCT are suitable for partial discharge detection of high-voltage switchgear and ring network cabinet; Ultrasonic and UHF are suitable for detection of insulating status of GIS; Ultrasonic and HFCT are suitable for detection of insulating status of power cable. The built-in expert diagnosis system can analyze the test data and judge the discharge energy and possible parts. It is widely used in electric power and railway.

  • GDPD-505 Portable Partial Discharge Detector

    GDPD-505 Portable Partial Discharge Detector

    GDPD-505 is a portable multi-functional PD online detector, which is suitable for testing transformers, GIS, switch cabinet, power cables, lightning arrester and CT/PTs.

    The system includes detector, software, HFCT(high frequency current transformer), calibration pulse generator, 40kHz ultrasonic sensor, 150kHz ultrasonic sensor, UHF sensors, TEV sensors, Acoustoelectric sensors and some connection cables.

    It uses pulse current, ultrasonic and UHF technology, to detect and analyze HF electromagnetic signals and ultrasonic signals of internal transformers and GIS, so that to detect and evaluate the running status of GIS, transformers.

     

     

     

     

     

     

  • HV-OWS-63 Oscillating Wave Test System (OWTS) for On-site PD Diagnostics of Cables

    HV-OWS-63 Oscillating Wave Test System (OWTS) for On-site PD Diagnostics of Cables

    HV-OWS-63 Oscillating Wave Test System (OWTS) for On-site PD Diagnostics of 10KV Cables is an integrated partial discharge location and management system. Partial discharge test with DAC waves,Test frequency varies from 50Hz to hundreds of Hertz under damping AC voltage.

  • GD-875/877 Thermal Infrared Camera

    GD-875/877 Thermal Infrared Camera

    GD-875/877 infrared camera uses 25μm 160*120 detector, temperature measurement range -20℃–+ 350℃, 3.5inch TFT LCD screen.

     

     

     