Partial Discharge Online Test

  • GDYT-150kW  PD-free Induced Voltage Test System

    GDYT-150kW PD-free Induced Voltage Test System

    This partial-discharge-free induced withstand voltage test system is designed for testing power transformers with rated capacities of 3,000kVA to 5,000kVA and rated voltages of 34.5 kV or below. Utilizing a high-precision, low-interference partial discharge detection system, it accurately reflects the transformer’s insulation condition, providing a reliable basis for factory acceptance tests, handover tests, and preventive maintenance, ultimately ensuring the safe, stable, and long-term operation of the power equipment.

  • GDUI-511PD Acoustic PD Camera | Handheld Acoustic Imager for Partial Discharge & Gas Leak Detection

    GDUI-511PD Acoustic PD Camera | Handheld Acoustic Imager for Partial Discharge & Gas Leak Detection

    GDUI-511PD Acoustic PD Camera, using high sensitivity digital microphone array, is mainly used to detect the leakage of pressurized gas and partial discharge of electrical insulation equipment, and can be extended to detect infrared thermal imaging, internal leakage or other detection functions.

    It features built-in flash lights for low-light detection and supports external sensor integration. The aluminum alloy casing enhances durability, while the explosion-proof design meets structural and circuit requirements. Some models are certified for explosion-proof environments (ensure your purchase is explosion-proof certified).

  • GDYT-10kW PD-Free Induced Voltage Test System | 10kW/100kV Variable Frequency Partial Discharge Test Set

    GDYT-10kW PD-Free Induced Voltage Test System | 10kW/100kV Variable Frequency Partial Discharge Test Set

    GDYT-10kW PD free induced voltage test set is variable frequency AC power supply (hereinafter called VF power supply). It inputs single AC voltage and frequency, after inversion, it generates stable and pure sine wave.

    The equipment uses PWM (Pulse Width Modulation) technology to make the device small size, light weight and highly efficient. Digital signal processing technology provides high-precision and high-speed measurement functions such as voltage, frequency, current, apparent power, and power factor. Meanwhile, it use high-power IGBT module design to reduce circuit complexity, improve product stability, reduce power consumption, and increase the capacity of a single unit, plus a number of ultra-isolation transformers to completely isolate the mains and the load to increase the functions, which can ensure the accuracy.

  • GDPD-PTU PD Online Monitoring System for Oil Transformer

    GDPD-PTU PD Online Monitoring System for Oil Transformer

    The aging and damage of the internal insulation of the transformer mostly starts from local discharge. The reason for local discharge is that the electric field is too concentrated at a certain point, or the electric field strength at a certain point is too large. At present, the main methods for detecting transformer local discharge faults are: UHF ultra-high frequency monitoring method, HFCT high-frequency pulse current local discharge measurement method (pulse current method), ultrasonic local discharge measurement method (ultrasonic method), and oil gas chromatography analysis method.

  • Partial Discharge Online Monitoring System of Generators

    Partial Discharge Online Monitoring System of Generators

    Generally, partial discharge occurs at a position where the properties of the dielectric material are not uniform.

  • Partial Discharge Online Monitoring System of GIS

    Partial Discharge Online Monitoring System of GIS

    Gas-insulated metal-enclosed switches (GIS) and gas-insulated metal-enclosed transmission lines (GIL) are one of the most important devices in the power system. They have the dual tasks of control and protection. 