  • OEM Best Abrasion Resistance Tester Exporters –  GDHL-100A Micro-Ohmmeter – HV Hipot

    OEM Best Abrasion Resistance Tester Exporters – GDHL-100A Micro-Ohmmeter – HV Hipot

    General Information GDHL-100A Micro-Ohmmeter is widely used to measure loop resistance and contact resistance for weld joints, cables, and various HV switches within power industry. It uses intelligent power test system “Smart-Quick”, which is granted software copyright, and advanced detection technology. Features ● Adopt high-precision constant current power supply, automatic rising current mode without manual adjustment, the test is fast and accurate. ● Use four-terminal w...
  • China High Quality flat tension tester Manufacturers –  GDOH-II insulating Oil Gas Content Tester – HV Hipot

    China High Quality flat tension tester Manufacturers – GDOH-II insulating Oil Gas Content Tester – HV Hipot

    General Information  GDOH-II Insulating Oil Gas Content Tester is a new generation tester adopts imported high accuracy sensor and the newest sensor technology. It is based on the DL423-91 power industry standard and relevant national standards. It is more practical, more stable and reliable in performance, easy to operate and more suitable for the determination of gas content in ultra-high voltage oil-filled equipment. It is an ideal test equipment for laboratory. Features ● The all-me...
  • China High Quality Capacitor Discharge Tool Factory –  Partial Discharge Test System GDYT series – HV Hipot

    China High Quality Capacitor Discharge Tool Factory – Partial Discharge Test System GDYT series – HV Hipot

    GDYT is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power supply for testing object such as transformer, mutual inductor and lightning arresters. It widely used in electrical manufacturing, power operation departments, research institutes and universities. It includes below components 1. Hipot Test Control Unit GDYD 2. PD-free Gas type transformer YDQW 3. C...
  • OEM Best 5kv megger Factory –  GDF-3000A  DC System Earth Fault Detector – HV Hipot

    OEM Best 5kv megger Factory – GDF-3000A DC System Earth Fault Detector – HV Hipot

    General Information DC system insulation faults, DC mutual faults and AC power failures are faults that are prone to occur and are harmful to the power system, and endanger the normal operation of the power system. In order to better help field maintenance personnel to quickly and accurately find DC faults, our company has developed a DC fault finder by years of efforts and summing up a large number of field experiences. The DC grounding finder uses a high-precision current clamp meter to ...
  • OEM Best Capacitance Is Measured By Manufacturer –  Partial Discharge Test System GIT series – HV Hipot

    OEM Best Capacitance Is Measured By Manufacturer – Partial Discharge Test System GIT series – HV Hipot

    GIT Series GIS High Voltage Test Sets integrate the high voltage boosting, high voltage measurement, high voltage transformer, high voltage coupling capacitors and all components in a sealed space. There are two modes to generate high voltage 1) Using reactor inductance and test object capacitance to realize voltage resonance test, to obtain a high voltage, high current from test object. 2) The other one is to obtain required high voltage directly from high voltage transformer. It is widely u...
  • China High Quality Gas Detection Equipment Factory –  GDP-8000CM SF6 Gas Dew Point Tester (Chilled Mirror Method)  – HV Hipot

    China High Quality Gas Detection Equipment Factory – GDP-8000CM SF6 Gas Dew Point Tester (Chilled Mirror Method) – HV Hipot

    General Information GDP-8000CM Portable Chilled Mirror SF6 Gas Dew Point Tester is specially designed for SF6 gas micro moisture detection used in the whole temperature zone of the power industry, which is based on Stryn refrigeration and chilled mirror measuring principle. It not only solved the problem that Peltier’s refrigeration principle mirror surface dew point tester could not be used in the high temperature field, but also solved the problem that the test data of the resistiv...
  • OEM Best Capacitor Checking Meter Supplier –  DC Hipot Test Set GDZG-S – HV Hipot

    OEM Best Capacitor Checking Meter Supplier – DC Hipot Test Set GDZG-S – HV Hipot

    Features ● Electronic control and tune, easy to operate. ● The date of voltage and current are recorded in the panel, reading without conversion. ● One minute timing and tip function. ● Perfect overvoltage and over-current protection function inside, also zinc oxide overvoltage protection outside, which ensure safety of generator. ● Both control unit and doubler packed with special shockproof aluminum alloy cabinet, easy to move. ● Portable design, suitable for on-site testing. Specific...
  • China High Quality Sf6 Purification Suppliers –  GDJD-3A SF6 gas Density Relay Calibrator – HV Hipot

    China High Quality Sf6 Purification Suppliers – GDJD-3A SF6 gas Density Relay Calibrator – HV Hipot

    Product Description GDJD-3A SF6 gas Density Relay Calibrator is automatic calibrator, which uses embedded microprocessor to proceed performance calibration for all kinds of SF6 gas density relay. It is also a portable device which can make standard conversion for SF6 gas pressure at any environmental temperature. This device is mainly used for SF6 gas products production, maintenance and monitoring in power system. Features ● Automatically calibrate density relay and pressure gauge. ● C...
  • China High Quality partial discharge detector Manufacturer –  Partial Discharge Online Monitoring System of Generators – HV Hipot

    China High Quality partial discharge detector Manufacturer – Partial Discharge Online Monitoring System of Generators – HV Hipot

    General Information Generally, partial discharge occurs at a position where the properties of the dielectric material are not uniform. At these locations, the local electric field strength is enhanced, and local electric field strength is too large, resulting in local breakdown. This partial breakdown is not the total breakdown of the insulating structure. Partial discharges typically require a certain amount of gas space to develop, such as gas voids inside the insulation, adjacent conduc...
  • OEM Best High Voltage Impulse Generator Supplier –  GDCL-10kA Impulse Current Generator – HV Hipot

    OEM Best High Voltage Impulse Generator Supplier – GDCL-10kA Impulse Current Generator – HV Hipot

    Working Environment ● Environmental temperature: -10℃ to 40℃ ● Related humidity: ≤ 85% RH ● Altitude: ≤ 1000m ● Indoor use ● No conductive dust, no fire or explosive danger, no corrosive metal or insulation gas. ● Power voltage waveform is sine wave, distortion rate <5% ● Earth resistance is no more than 1Ω. Applied Standard IEC60099-4: 2014 Surge Arresters-Part 4: Metal-oxide surge arresters without gaps for a.c. systems. GB311.1-1997 Insulation coordination of HV Power transmission...
  • OEM Best Lightning Arrester Suppliers –  GDYZ-301 Zinc Oxide Surge Arrester Tester  – HV Hipot

    OEM Best Lightning Arrester Suppliers – GDYZ-301 Zinc Oxide Surge Arrester Tester – HV Hipot

    Features 1. 800*480 color LCD touch screen, with high speed thermal printer. 2. Graphic display, intuitive interface, easy to operate and use on-site. 3. Long distance wireless transmission. PT signal wireless transmission distance more than 400m (2000m can be customized). 4. Suitable for testing in various situation such as lightning arrester with or without electricity, laboratory. 5. Test three phase current, three phase voltage at the same time, more efficient. 6. No strong electricity...
  • China High Quality low cost insulation tester Suppliers –  GDCR3200C Double Clamp Multifunctional Earth Resistance Tester – HV Hipot

    China High Quality low cost insulation tester Suppliers – GDCR3200C Double Clamp Multifunctional Earth Resistance Tester – HV Hipot

    General Information GDCR3200C Double Clamp Multifunctional Earth Resistance Tester is specially designed and manufactured for on-site measurement of grounding resistance, soil resistivity, grounding voltage, grounding line leakage current, AC current and DC resistance. The instrument adopts advanced digital processing technology, with 2-wire method, 3-wire method, 4-wire method, selection method, double clamp method and other measurement methods; Import FFT (Fast Fourier Transform) technol...