HPCI-5000A Primary Current Injection Test Set | 5000A High Current Generator & PCI Tester
HPCI -5000A Primary Current Injection Test Set is a professional testing device independently developed by HV HIPOT Company. It can output high amplitude current to test the performance indicators of various equipment under the rated current conditions. It adopts high-precision numerical control technology to effectively avoid the influence of external interference on the test data; it uses a converter made of low-power consumption, large-capacity autotransformer and high magnetic permeability core, which has the advantages of large output power, small size and light weight.
-
HCB-14 Circuit Breaker Analyzer | 12-Channel High Voltage Switchgear Dynamic Characteristics Tester
HCB-14 Circuit Breaker Analyzer is widely applicable to mechanical characteristics testing scenarios for various types of high-voltage switchgear, including vacuum switches, SF6 switches, and oil switches. It meets the testing needs of power system switchgear in various scenarios, including factory inspection, operation and maintenance testing, overhaul and commissioning, and scientific research testing, providing professional data support for the safe and stable operation of switchgear.
-
GDSL-A-5000A/10V Single Phase Primary Current Injection Test Set
GDSL-A-5000A/10V Single Phase Primary Current Injection Test Set uses a PLC and a 19-inch industrial tablet computer as its control system, enabling both manual and automatic temperature rise testing. This test device can output a single-phase current of 5000A and collect data from 16 temperature sensors. It displays the collected temperature and current data in the form of graphs and can export the data as a CSV file for easy analysis and processing on a computer. The device also features comprehensive protection measures.
-
HPCI SER. Primary Current Injection Test Set
HPCI SER. Primary Current Injection Test Set uses digital control technology, with strong anti-interference ability.It features a low-power, high-capacity auto-coupled voltage regulator and a current transformer built with a high-permeability iron core, resulting in high output power, compact size, and light weight. It is mainly used for primary busbar protection and various current transformer ratio tests, and is widely used in scientific research, production, and electrical testing at power, railway, petrochemical, metallurgical, and mining companies.
-
GDKC-15D Circuit Breaker Analyzer
High voltage circuit breaker is one of the most important control equipment in the power system. GDKC-15D circuit breaker analyzer is used to test the dynamic characteristics of high voltage circuit breaker. It is easy to operate, with high accuracy.
-
GDKC-15A Circuit Breaker Analyzer
High voltage circuit breaker is one of the most important control equipment in the power system.
GDKC-15A circuit breaker analyzer is used to test the dynamic characteristics of high voltage circuit breaker. It is easy to operate with high accuracy.
-
GDSL-D-5000A/6V Primary Current Injection Test Set
Primary Current Injection Test Set, is the ideal equipment for testing high-current device in the power and electric industry, used in power plants, distribution stations, electrical manufacturing and research institutes, with the features of small size, light weight, easy to use and maintenance.
-
GDGK-601 Switch Power Supply Box
GDGK-601 switch operation power supply box is a special power supply designed for the detection and maintenance of high-voltage switch opening and closing coils and their operating mechanisms. It has the advantages of adjustable voltage, simple operation, small size, and easy to carry. It is an indispensable detection tool for high-voltage switch maintenance.
-
GDAS-500 DC Circuit Breaker Test Set
Circuit Breakers are one of the critical “safety-valves”of electrical systems and basic maintenance procedures are essential to maintain maximum reliability.
According to the actual situation of the DC circuit breaker ampere-second characteristic test system, our company has introduced a DC circuit breaker ampere-second characteristic test system suitable for substation site use, easy to carry, and high degree of automation. It can provide DC protection for the operation and maintenance department. Characteristic testing methods are used to verify the action characteristics and level difference coordination of DC protection appliances, to improve the reliability of the DC system operation and ensure the safe and reliable operation of the power grid.
-
GDSL-A Automatic 3-phase Primary Current Injection Test Set with Temperature Test
GDSL-A Series 3-phase Primary Current Injection Test Set with Temperature Test is the ideal equipment for testing high-current device in the power and electric industry, used in power plants, power distribution stations, electrical manufacturing and research institutes, with the features of small size, light weight, easy use and maintenance.
-
GDZK-IV Vacuum Degree Tester for Vacuum Breaker
GDZK-IV is designed to measure the vacuum degree of vacuum breakers. It uses an electromagnetic discharge measuring method, to ensure the testing results accurate and reliable.The testing data can estimate vacuum breaker’s health and life span.
-
GDSL-BX-100 Primary Current Injection Test Set
GDSL-BX-100 Primary Current Injection Test Set, is mainly used for testing current transformer, motor protector, air switch, switch cabinet, circuit breaker, protection screen and etc.