SF6 Gas Recycling System

  • GDQH-601-200    SF6 Gas Recovery Unit

    GDQH-601-200 SF6 Gas Recovery Unit

    GDQH-601-200 SF6 gas recovery unit is manufactured according to the DL/T662-1999 standard “Sulfur Hexafluoride Charging and Recovery Device”. It consists of an SF6 compressor, vacuum pump, vacuum system with anti-oil-back device, condensation system, liquid storage tank, purification system with built-in regenerable dryer filter, dust filter, ball valve, vacuum gauge, and auxiliary facilities such as electrical control, pressure detection, thermometer and alarm devices, and control and instrument panel.

     Suitable for manufacturers of SF6 electrical appliances, GIS combined electrical appliances, and SF6 gas-insulated electrical equipment, as well as for users, operating and research departments.

  • GSH-C-NYA-30/60 SF6 Gas Recovery Machine (200L Storage Tank)

    GSH-C-NYA-30/60 SF6 Gas Recovery Machine (200L Storage Tank)

    This machine includes an SF6 compressor, a vacuum pump, a vacuum system with an anti-oil return device, a liquid storage tank, a purification system with a built-in regenerative dryer filter, a dust filter, a ball valve, a vacuum gauge, and auxiliary facilities such as electrical control, pressure detection, thermometer and alarm devices, and control and instrument panel.It is suitable for SF6 electrical equipment, GIS manufacturer and institute.

  • GSH-C-YNA-11/45 SF₆ Gas Recovery Machine | Built-in 300L Storage Tank

    GSH-C-YNA-11/45 SF₆ Gas Recovery Machine | Built-in 300L Storage Tank

    GSH-C-YNA-11/45 Intelligent SF₆ Gas Recovery, Purification, Vacuumizing and Refilling Integrated Machine with 300L Built-in Liquefied Storage Tank, for On-Site Maintenance of Medium-Voltage SF₆ Switchgear, Circuit Breakers and Instrument Transformers.

  • GSH-NNA-30/250-400 Mobile Heavy-Duty SF₆ Gas Recovery Unit

    GSH-NNA-30/250-400 Mobile Heavy-Duty SF₆ Gas Recovery Unit

    GSH-NNA-30/250-400 heavy-duty SF6 gas recovery unit: 30m³/h recovery rate, 250m³/h high-capacity vacuum, 400kg liquefied storage. Integrates recovery, vacuum, deep purification, liquefaction and refilling. PLC auto control, multi-stage safety protection. Mobile industrial design for large GIS & EHV switchgear.

  • GDQH-31H Portable SF6 Gas Recovery Device

    GDQH-31H Portable SF6 Gas Recovery Device

    GDQH-31W Portable SF6 Gas Recovery Device (MINI) is used in the manufacturing plant of SF6 gas insulated electrical equipment and operation & scientific research departments to fill electrical equipment with SF6 gas and recover SF6 gas from electrical appliances used or tested.

    At the same time, it is purified and compressed and stored in the storage tank. Suitable for ring network distribution network below 50kV. 

  • GDQH-601-50 SF6 Gas Recycling Machine

    GDQH-601-50 SF6 Gas Recycling Machine

    The model GDQH-601-50 is special machine of vacuumizing and filling device. It is suitable for SF6 electrical equipment, GIS manufacturer and research institute.

  • GDQC-55A SF6 Gas Vacuuming and Filling Machine

    GDQC-55A SF6 Gas Vacuuming and Filling Machine

    GDQC-55A SF6 Gas Vacuuming and Filling Machine is mainly used for vacuuming and filling SF6 gas insulated electrical equipment in the manufacturing, use and scientific research departments.

    It is suitable for SF6 electrical equipment, GIS manufacturer and research institute.

  • GDQH-31W Portable SF6 Gas Recovery Device

    GDQH-31W Portable SF6 Gas Recovery Device

    GDQH-31W Portable SF6 Gas Recovery Device (MINI) is used in the manufacturing plant of SF6 gas insulated electrical equipment and operation & scientific research departments to fill electrical equipment with SF6 gas and recover SF6 gas from electrical appliances used or tested.

    At the same time, it is purified and compressed and stored in the storage tank. Suitable for ring network distribution network below 50kV. 

      

     

     

     

  • GDQC-16A(mini) SF6 Vacuum Pumping and Filling Device

    GDQC-16A(mini) SF6 Vacuum Pumping and Filling Device

    GDQC-16A Gas Vacuum Pumping and Filling Device is mainly used as auxiliary equipment of gas equipment GCBT, GIS, SF6 during installing, debugging and repairing in various power supply companies, power transmission engineering companies, power plants, ultra high voltage transmission,  SF6 gas electrical switch manufacturing plant and other departments.

     