Insulation Resistance Tester

  • MRT-15 15kV Insulation Resistance Tester | High Voltage Megohmmeter with IR/PI/DAR/DD/SV Testing

    MRT-15 15kV Insulation Resistance Tester | High Voltage Megohmmeter with IR/PI/DAR/DD/SV Testing

    MRT-15 Insulation Resistance Tester is widely used in maintenance of electrical equipment in transformer substation, power plant, etc. It is suitable for carrying out measurement of insulation resistance (IR), absorption ratio (DAR) and polarization index (PI) of all kinds of high voltage equipment, including switch-gear, transformers, reactors, capacitors, motors, generators and cables, etc.

  • MRT-5 5kV Portable Transformer Megohmmeters IR Insulation Resistance Tester 10TΩ Diagnostic Analyzer

    MRT-5 5kV Portable Transformer Megohmmeters IR Insulation Resistance Tester 10TΩ Diagnostic Analyzer

    MRT-5 HV Insulation Tester is a professional instrument developed and produced by HV HIPOT in accordance with IEC 61010-1 and other relevant standards. It is used to measure the insulation resistance of power transformers, cables, motors, lines and materials. It uses high-voltage DC injection technology to output a stable DC voltage to the device under test through an internal precision high-voltage generator, accurately measuring the leakage current and automatically calculating the insulation resistance value. 

  • MRT-10 Portable 10kV Insulation Resistance Tester for Transformer & Cable Diagnostic Testing

    MRT-10 Portable 10kV Insulation Resistance Tester for Transformer & Cable Diagnostic Testing

    MRT-10 High Voltage Insulation Resistance Tester is a professional instrument developed and produced by HV HIPOT in accordance with IEC 61010-1 and other relevant standards. It is used to measure the insulation resistance of power transformers, cables, motors, lines and materials. It uses high-voltage DC injection technology to output a stable DC voltage to the device under test through an internal precision high-voltage generator, accurately measuring the leakage current and automatically calculating the insulation resistance value. 

  • GD3127 Series High Voltage Insulation Resistance Tester

    GD3127 Series High Voltage Insulation Resistance Tester

    GD3127 Series Insulation Resistance Tester is widely used in maintenance of electrical equipment in transformer substation, power plant, etc.

  • GD2000H 10kV Insulation Resistance Tester

    GD2000H 10kV Insulation Resistance Tester

    This device can test insulation resistance (such as transformer, switchgear, leads, motor) of different modules in one system, to insulate and repair failure components.

  • GD2000D Insulation Resistance Tester

    GD2000D Insulation Resistance Tester

    GD2000D digital insulation resistance tester produced by our company uses an embedded industrial single chip real-time operating system. The digital analog pointer and digital field code display are perfectly combined.

     

  • GD3126A (GD3126B) Insulation Resistance Tester 5kV/10TΩ (10kV/20TΩ)

    GD3126A (GD3126B) Insulation Resistance Tester 5kV/10TΩ (10kV/20TΩ)

    It is suitable for carrying out measurement of insulation resistance (IR), absorption ratio (DAR), polarization index (PI), leakage current (Ix) and absorption capacitance (Cx) of all kinds of high voltage equipment, including switchgear, transformers, reactors, capacitors, motors, generators and cables, etc.

     

  • GD3128 Series Insulation Resistance Tester

    GD3128 Series Insulation Resistance Tester

    GD3128 series Insulation Resistance Tester has perfect testing function of various insulation resistance parameters and excellent anti-interference ability, which can be used to test the insulation resistance of large capacity high voltage electrical equipment and transmission lines in strong inductive environment such as substation. 