Oil Test Equipment

  • GDKS-205A Automatic Flash Point Open Cup Tester

    GDKS-205A Automatic Flash Point Open Cup Tester

    GDKS-205A automatic open cup flash point tester is the device testing open cup flash point for petroleum products. It use module design which one host can control several testing furnace, to test different samples at the same time or separately. The testing furnace port can be connected to the host disorderly. It widely used in the field of railway, air company, power, petroleum and research department.

  • GDBS-305A Automatic Flash Point Closed Cup Tester

    GDBS-305A Automatic Flash Point Closed Cup Tester

    GDBS-305A automatic closed cup flash point tester is the device testing closed cup flash point for petroleum products. It widely used in the field of railway, air company, power, petroleum, and research department.

  • GDW-106 Intelligent Oil Dew Point Meter&Micro-Moisture Tester

    GDW-106 Intelligent Oil Dew Point Meter&Micro-Moisture Tester

    The warranty period for this series is ONE year from the date of shipment, please refer to your invoice or shipping documents to determine appropriate warranty dates. HVHIPOT corporation warrants to the original purchaser that this product will be free from defects in material and workmanship under normal use.

  • GDZL-503 Automatic Interfacial Tension tester

    GDZL-503 Automatic Interfacial Tension tester

    Intermolecular forces will generate interface tension and surface tension of liquids. The value of tension reflects liquid sample’s physics and chemical properties, which is one of the most important index for product quality. 

  • GDZD-601 Automatic Multi-Function Insulation Oil Shaker

    GDZD-601 Automatic Multi-Function Insulation Oil Shaker

    Multi-Function Shaker is used in laboratory to test heat, shake, degas various kinds of liquid under constant temperature and a fixed time. It is controlled by micro-computer to realize man-machine interaction.

  • GDYN-901 Kinematic viscosity tester

    GDYN-901 Kinematic viscosity tester

    GDYN901 is suitable to determine kinematic viscosity of liquid petroleum products. This apparatus has the function of timing of the trial sample movement and can calculate the final result of kinematic viscosity. 

     

  • GDND-800 Freezing Point Tester

    GDND-800 Freezing Point Tester

    Transformer oil freezing point tester has the characteristics of exquisite structural design and unique manufacturing process. It conforms to GB/T 3535 and GB/T510 standards and is used to determine the pour point of petroleum products.

  • GDCP-510 Oil Freezing Point Tester

    GDCP-510 Oil Freezing Point Tester

    GDCP-510 Low Temperature Freezing Point Tester is compliant with GB/T 510 “Determination of Solidification Point for Petroleum Products” and GB/T 3535 “Petroleum Products―Determination of Pour Point. 

  • GDKS-205  Automatic Flash Point Open Cup Tester

    GDKS-205 Automatic Flash Point Open Cup Tester

    GDKS-205 automatic open cup flash point tester is the device testing open cup flash point for petroleum products. It use module design which one host can control several testing furnace, to test different samples at the same time or separately. 

  • GDBS-305 Automatic Flash Point Closed Cup Tester

    GDBS-305 Automatic Flash Point Closed Cup Tester

    GDBS-305 automatic closed cup flash point tester is the device testing closed cup flash point for petroleum products. It use module design which one host can control several testing furnace, to test different samples at the same time or separately.

  • GDZL-50L Oil Filtration Machine

    GDZL-50L Oil Filtration Machine

    The machine GDZL-50L can effectively remove moisture, gas and impurities in the insulating oil, improve the pressure resistance of the oil and the quality of the oil, to ensure the safe operation of the power equipment.

     

  • GDSZ-402 Automatic Acid Value Tester

    GDSZ-402 Automatic Acid Value Tester

    Automatic Acid Value Tester is designed for testing acid value for transformer oil, turbine oil and fire resistant oil etc. PC control system can improve the work efficiency and reduce the harm in organic solvents and chemicals to human body.

     

12 Next > >> Page 1 / 2