-
VLF AC Hipot Test Set 80kV
Withstand voltage test is an essential preventive test for electrical equipment. It is divided into two parts: AC and DC withstand voltage test.
-
VLF AC Hipot Test Set
Withstand voltage test is an essential preventive test for electrical equipment. It is divided into two parts: AC and DC withstand voltage test.
-
GDTL- AC Inductance Resonance Test System for CVT
GDTL AC Resonant Test System for CVT is series resonance with power frequency specially for CVT.
-
GDTL AC Resonant Test System for Generators
GDTL series AC Resonant Test System for Generators can be used by adjusting inductance of the reactor, or adjusting the work way of resonant frequency of the system to achieve resonance.
-
GDTF Variable Frequency AC Resonant Test System
GDTF Series AC Resonant Test System For Cables are composed of frequency/voltage adjustment power supply, excitation transformer, reactors and capacitive divider.The power frequency can be adjustable, which make the reactor and tested capacitor resonance.
-
GDYD-2030A 30kVA.200kV Automatic AC/DC Hipot Test Set
GDYD-2030A Automatic AC/DC Hipot Test Set is composed of automatic control unit and gas testing transformer (HV unit) which output AC or DC voltage smoothly. Meanwhile, it has many monitoring and protection functions.
-
GDYD-53D 50kV AC DC Dielectric Test Equipment
AC hi-pot testing is the effective and direct way to test insulation strength for electrical equipment, apparatus, or machines. It checks dangerous flaws which assure electrical equipment continuous working.
-
GDZG-S DC Hipot Test Set
GDZG-S series is equipment of testing DC voltage and DC leakage current of water-cooled generator in the situation of water through, which completely overcome the problems of long blow water time, bottom water hard to dry, easy to cause arcing within the coil. The device is light, simple wiring, and easy to read. Polarization compensation voltage is output directly by the case.
-
GDZG-300 DC High Voltage Generator
GDZG-300 series of DC high voltage tester is testing DC high voltage for zinc oxide lighting arrester, magnetic blowing arrester, power cables, generators, transformers, switches, and other equipment, which is suitable for electric power branch, power department of factories, scientific research units, railway, chemical industry, power plants.
-
GDJS-65 Insulation Materials Hipot Test Set
It is used to test insulation performance for insulation gloves, boots, mats, hats, rod, Electroscope etc. It can test 6pcs insulation gloves/boots at the same time, also 5pcs insulation rods.
-
GDYD-M AC Dielectric Test Equipment with manual control unit
Typical applications include testing of transformers, switchgear, cables, capacitors, aerial motors platforms, hot sticks bucket bricks, vacuum bottles and other related equipment like vacuum interrupters, blankets, ropes, gloves, hydraulics hose, instruments transformers generators.
-
GDYD-D AC Dielectric Test Equipment With Manual Control Unit
AC Hipot testing is the effective and direct way to test insulation strength for electric equipment, apparatus, or machines. It checks dangerous flaws which assure electric equipment continuous working.