DRM-20M DC Winding Resistance Meter
DRM-20M DC Winding Resistance Meter is developed by taking full use of our technical advantages in order to meet the needs of fast measurement of transformer DC resistance. Boasting a large true color high-resolution LCD screen and adopting touch control and jog dial, it’s convenient to use on site. Featuring Chinese menu prompts, it’s simple and intuitive to operate. It’s fast to test with high accuracy and wide measurement range.
-
OTD-B Oil Tan Delta Tester
OTD-B Oil Tan Delta Tester is a compliant testing device specifically designed for the accurate measurement of dielectric loss factor and DC resistivity of liquid insulating media. The instrument features an innovative integrated architecture, highly integrating core components such as the dielectric loss oil cup, temperature control unit, precision test bridge, high-stability AC/DC power supply, standard capacitor, and high-resistance meter. This eliminates the need for cumbersome external components, allowing for fully automated operation of the heating, temperature control, testing, and analysis processes.
-
DRM-10 DC Winding Resistance Meter
DRM-10 DC winding resistance tester is a precision instrument that efficiently diagnoses potential problems such as coil material defects, poor welding, loose connections, and broken strands by measuring winding resistance values. It utilizes a high-precision constant current source and four-wire measurement technology to automatically eliminate lead errors, providing stable readings within 3 seconds. With a sensitivity of 0.1 μΩ, it can accurately detect subtle resistance changes, ensuring stable and reliable measurement results.
-
OVT-80T Insulation Oil Tester
The OVT-80T Insulating Oil Tester, developed and manufactured by HV HIPOT in accordance with relevant standards such as IEC 60156, ASTM D877, and ASTM D1816, is a professional instrument for testing the dielectric strength of insulating oils and evaluating their quality and performance. A single-chip microcomputer controls the internal boost system, applying an electric field and detecting the breakdown voltage of the insulating oil, providing a reliable basis for evaluating insulating oil quality.
-
DRM-20S DC Winding Resistance Tester
The DRM-20S three-phase DC winding resistance meter is a precision device that measures winding resistance to efficiently diagnose potential problems such as coil material defects, poor welding, loose connections, and broken wires. It integrates magnetic assist testing, three-phase testing (Yn, Y, and △ types), and demagnetization functions to fully meet the measurement needs of various winding structures.
-
OVT-80K Insulation Oil Tester
OVT-80K Insulating Oil Dielectric Strength Tester, developed and manufactured by HV HIPOT in accordance with relevant standards such as IEC 60156, ASTM D877, and ASTM D1816, is a professional instrument for testing the dielectric strength of insulating oils and evaluating their quality and performance.
-
TWR-S Transformer Turns Ratio Tester
TWR-S Transformer Turns Ratio Tester can be used for three-phase transformer testing in power systems, especially for Z-type winding transformers, rectifier transformers and Scott, reverse Scott, and balanced transformer testing in railway electrical systems. It is an ideal transformer ratio group polarity tester for power systems, transformer manufacturers and railway electrical systems.
-
GDYL-12kV/100pF Calibration Standard
The Standard Capacitor is a calibration instrument. It is standard capacitor for tan delta. When calibrating the test result, it can be tested as test object. User can compare the measured test result with former result.
-
GDZRS-40S DC Winding Resistance Tester
GDZRS series DC winding resistance is a mandatory test item during transformer manufacturing for semi-finished/finished products, factory acceptance tests, installation, commissioning tests, and utility preventive maintenance tests.
-
GDZRC-20U Series DC winding resistance tester
GDZRC series DC winding resistance tester is designed to measure DC resistance of inductive devices, such as transformers and power inductors.
It has the features of fast measurement, small size and high accuracy of measurement, which is ideal equipment of measuring transformer winding and DC resistance of big power inductance equipment. -
GD6900 Capacitance & Tan Delta Tester
GD6900 measures the capacitance and dielectric loss factor (tgδ) of high voltage electric equipment. It is integrated structure, built-in dielectric loss test bridge, variable frequency adjustable power supply, boosting transformer and SF6 standard capacitor.
-
GDZRS-20B Three Phase DC Winding Resistance Tester
GDZRS-20B Three Phase DC Winding Resistance Tester is a new generation of rapid tester that integrates magnetization method testing, three-phase testing (Yn, Y, △) and degaussing functions. It is an ideal equipment for measuring the DC resistance of large power transformers. The screen adopts a large-screen high-resolution LCD, which is convenient for on-site use. All direct resistance test items can be completed with one connection. The test speed is fast, the accuracy is high, and the measuring range is wide.