OTD-B Automatic Precision Oil Tan Delta Tester | Insulating Oil Dielectric Loss & Resistivity Analyzer
• Oil cup adopts a three-electrode structure with a 2mm electrode gap, reducing the influence of stray capacitance and leakage on the test results.
• Built-in SF6 gas-filled three-terminal standard capacitor ensures long-term stable accuracy.
• Medium-frequency induction heating combined with PID temperature control provides non-contact, uniform, and rapid heating with precise temperature control.
• Supports empty electrode cup calibration and automatically saves data to ensure accurate calculation of relative permittivity and DC resistivity.
• The AC power supply adopts an AC-DC-AC design, providing strong resistance to voltage and frequency fluctuations.
• The heating furnace is equipped with a temperature limiting relay, which automatically stops heating if the temperature exceeds the limit.
• Large-size LCD touch screen with a clear and intuitive interface, and test results can be automatically saved and printed.
• Built-in real-time clock, and the test time is saved, displayed, and printed along with the results.
• It supports an optional intelligent closed-loop automatic oil draining system, which automatically and accurately drains the oil after testing, ensuring no residue and accurate data.
• With multiple protection functions, including overvoltage, overcurrent, and high-voltage short circuit protection, and automatically cuts off the high voltage and triggers an alarm in case of abnormality.
| Power supply voltage | AC 220V±10%
Capacitance Accuracy: ±(1%D+0.5pF) Relative Permittivity Accuracy: ±1%D Dielectric Loss Factor Accuracy: ±(1%D+0.01%) DC Resistivity Accuracy: ±10%D Capacitance Resolution: 0.01 pF Relative Permittivity Resolution: 0.001 Dielectric Loss Factor Resolution: 0.001 % DC Resistivity Resolution: 0.0001 |
| Power supply frequency | 50/60 (1±5%) Hz |
| Measurement range | Capacitance: 5pF~200pF
Relative permittivity: 1.000~30.00 Dielectric loss factor: 0.000%~100% DC resistivity: 2.5MΩm~20TΩm |
| Measurement accuracy | Capacitance: ±(1%D + 0.5pF)
Relative permittivity: ±1%D Dielectric loss factor: ±(1%D + 0.01%) DC resistivity: ±10%D |
| Resolution | Capacitance: 0.01 pF
Relative permittivity: 0.001 Dielectric loss factor: 0.001 % DC resistivity: 0.0001 |
| Temperature measurement range | Room temperature to 120℃ |
| Temperature measurement error | ±0.5℃ |
| Temperature control accuracy | ±1℃ |
| AC test voltage | 500–2000V, accuracy: 3%, continuously adjustable |
| DC test voltage | 300–500V, accuracy: 3%, continuously adjustable |
| Power supply power | 300W |
| Oil cup electrode distance | 2mm |
| Empty cup capacitance | 60±5PF |
| Maximum test voltage | Power frequency 2000V |
| Dielectric loss of empty cell | tgδ < 1×10-4 |
| Liquid volume | Approximately 40ml |
| Electrode material | 316L stainless steel |
| Ambient temperature | 0℃~40℃ |
| Relative humidity | <75% |