China High Quality 1000v Capacitor Exporters – Partial Discharge Test System GDYT series – HV Hipot
China High Quality 1000v Capacitor Exporters – Partial Discharge Test System GDYT series – HV Hipot Detail:
GDYT is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power supply for testing object such as transformer, mutual inductor and lightning arresters. It widely used in electrical manufacturing, power operation departments, research institutes and universities.
It includes below components
1. Hipot Test Control Unit GDYD
2. PD-free Gas type transformer YDQW
3. Coupling capacitor
4. Protective resistor
5. Isolation filter LBQ
6. Partial discharge detector
Features
● Advanced PD-free epoxy insulating tube, small partial discharge capacity.
● Low impedance voltage, better than national standard.
● Automatic control technology, good anti-interference performance.
● Rapid electronic protection, high reliability.
Specifications
● Rated Capacity (KVA) : 5~5500
● High Voltage (KV): 50~250
● Low Voltage (KV): 0.22/0.38~0.38/0.6~0.6/3~3/6/10
● Top cover(mm): accordance with specific conditions
| Model | Rated Capacity | High Voltage | Low Voltage | Top cover OD x Height | Weight |
| (KVA) | (KV) | (KV) | (mm) | (KG) | |
| GDYT-5/50 | 5 | 50 | 0.22/0.38 | 320×450 | 42 |
| GDYT-50/50 | 50 | 50 | 0.22/0.38 | 850×945 | 360 |
| GDYT-10/100 | 10 | 100 | 0.22/0.38 | 570×725 | 150 |
| GDYT-50/100 | 50 | 100 | 0.22/0.38 | 850×1000 | 400 |
| GDYT-100/100 | 100 | 100 | 0.22/0.38 | 850×1000 | 800 |
| GDYT-15/150 | 15 | 150 | 0.22/0.38 | 1165×1400 | 500 |
| GDYT-75/150 | 75 | 150 | 0.22/0.38 | 1350×1570 | 1100 |
| GDYT-150/150 | 150 | 150 | 0.38/0.6 | 1350×1570 | 1400 |
| GDYT-20/200 | 20 | 200 | 0.22/0.38 | 1165×1850 | 760 |
| GDYT-100/200 | 100 | 200 | 0.22/0.38 | 1450×1950 | 1800 |
| GDYT-200/200 | 200 | 200 | 0.38/0.6 | 1800×1950 | 3100 |
| GDYT-25/250 | 25 | 250 | 0.22/0.38 | 1250×2200 | 1250 |
| GDYT-150/250 | 150 | 250 | 0.38/0.6 | 1450×2200 | 1900 |
| GDYT-250/250 | 250 | 250 | 0.38/0.6 | 2000×2300 | 3100 |
| GDYT-500/250 | 500 | 250 | 3/6 | 200×2600 | 5800 |
| GDYT-1000/250 | 1000 | 250 | 3/6 | 2200×2600 | 8200 |
Product detail pictures:
Related Product Guide:
We've been commitment to offer the competitive rate ,outstanding merchandise good quality, too as fast delivery for China High Quality 1000v Capacitor Exporters – Partial Discharge Test System GDYT series – HV Hipot , The product will supply to all over the world, such as: Peru, Comoros, Japan, Custom orders are acceptable with different quality grade and customer's especial design. We are looking forward to establish the good and successful cooperation in business with long terms from the customers of all over the world.