China High Quality 50 Kv Capacitor Suppliers – AC DC High Voltage Divider – HV Hipot
China High Quality 50 Kv Capacitor Suppliers – AC DC High Voltage Divider – HV Hipot Detail:
GDFR-C1 series AC/DC Voltage Meter
GDFR-C1 series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. It consists of voltage divider and measurement instrument.
Features
● Balance type equal potential shield structure.
● Fully-sealed insulation cylinder with internal excellent components.
● High accuracy and linearity, good stability and anti-interference ability.
● The voltage ratio can be customized, suitable for calibration.
● Upside down is forbidden when installation.
Technical Specifications
| Model No. | GDFR-C1-50 | GDFR-C1-100 | GDFR-C1-150 | GDFR-C1-200 | GDFR-C1-300 | GDFR-C1-400 |
| Voltage(kV) | 50 | 100 | 150 | 200 | 300 | 400 |
| DC frequency (Hz) | <2 | |||||
| AC frequency (Hz) | 30-300 | |||||
| Accuracy | AC: 1.5%/DC: 1.0% | |||||
| Accuracy for option (G type) | AC: 1.0%/DC: 0.5% | – | ||||
| Accuracy for option (H type) | AC: 0.5%/DC: 0.5% | – | – | |||
| Impedance (MΩ) |
650 | 1280 | 2000 | 2640 | 4000 | 5360 |
| Capacitance (pF) |
320 | 250 | 400 / 160 | 300 | 200 | 300 |
| Voltage ratio | 1000:1 or 10000:1(or customized) | |||||
| Dimension (mm) |
150×150 | 160×160 | 350×350 | 800×800 | 1000×1000 | |
| Cable impedance(Ω) | 50 / 75 | |||||
| Range | 1. Low range: 0-20kV 2. High range: 20kV-rated voltage 3. Low range: 0-200kV 4. High range:200kV-rated voltage |
|||||
| Cable length(m) | 3 | 4 | 6 | 6 | 10 | 10 |
| Weight(kg) | 5.5 | 9.5 | 12.5 | 14.5 | 27 | 40 |
| Packing Medium | Polyurethane foaming agent | |||||
| Operation temperature | 0℃-45℃ | |||||
| Relative humidity | <85%RH, no condensation | |||||
| Altitude | <1500m (or customized) | |||||
| Use condition | Indoor use or outdoor use in Sunny day | |||||
Product detail pictures:
Related Product Guide:
Every member from our high efficiency sales team values customers' needs and business communication for China High Quality 50 Kv Capacitor Suppliers – AC DC High Voltage Divider – HV Hipot , The product will supply to all over the world, such as: Oslo, Costa Rica, Sri Lanka, We have many years' experience in hair product production, and our strict QC Team and skilled workers will ensure that we give you top hair products with the best hair quality and workmanship. You will get successful business if you choose to cooperate with such a professional manufacturer. Welcome your order cooperation!