China High Quality Arbitrary Waveform Factories – GDBR-P Transformer Load, No-load and Capacity Tester – HV Hipot
China High Quality Arbitrary Waveform Factories – GDBR-P Transformer Load, No-load and Capacity Tester – HV Hipot Detail:
Features
● Measure transformer No-load current, No-load loss, short circuit voltage, short circuit loss and capacity.
● Three meters testing methods.
● When making three phase transformer No-load, load test, the instrument will judge if the wiring is correct automatically, and shows three phase voltage, current vector diagram.
● Finish load test under 1600kVA below distribution transformer full current for single machine. Finish 2500kVA below distribution transformer load test under 1/3 rated current (Under 1/3 rated current, the instrument can be converted to load loss parameters under rated current.)
● All test results are corrected automatically. The instrument automatic correction as follows, waveform correction, temperature correction, Non rated voltage correction and non rated current correction. The test results are more accurate.
● 320*240 high brightness LCD screen, with brightness adjustment. Touch buttons make the operation more convenient.
● Real-time clock, recording test date automatically, suitable for storage and management of test results.
● Built-in panel-type thermal printer, fast print test results.
● Power down store and browse data (test object set, measurement results, test time) functions. Store up to 500groups test results, data transmission online to PC.
● Allows extended range measurement for external voltage transformer and current transformer. Measure test object of any parameters.
Specifications
1. Test items
● RMS of three phase voltage: Uab,Ubc,Uca.
● Average value of three phase AC voltage: Uab,Ubc,Uca.
● RMS of three phase current: Ia, Ib, Ic.
● Percentage of No-load loss and No-load current: Po, Io%.
● Load loss, impedance voltage percentage, short circuit impedance: Pt, ekt, Zt.
● Load loss, impedance voltage percentage and short circuit impedance at any specified temperature.
● Transformer actual capacity and judged capacity.
2. Main technical parameters
● Current measurement range: 100mA-60A,accuracy:class 0.2.
● Voltage measurement range: 10V-650V,accuracy:class 0.2.
● External transformer can broaden the measurement range of instrument.
● Frequency measurement range: 40-65Hz, accuracy:class 0.2.
● Power input: AC220V± 10%.
Packing List
| Main Unit | 1 pc |
| Power cord | 1 pc |
| Clamp testing cable | 1 set |
| Special short-circuit cable | 1 pc |
| User’s guide | 1 pc |
| Factory test report | 1 pc |
Product detail pictures:
Related Product Guide:
We've been committed to offering easy,time-saving and money-saving one-stop purchasing support of consumer for China High Quality Arbitrary Waveform Factories – GDBR-P Transformer Load, No-load and Capacity Tester – HV Hipot , The product will supply to all over the world, such as: Hongkong, Portugal, Costa Rica, Due to our strict pursues in quality, and after-sale service, our product gets more and more popular around the world. Many clients came to visit our factory and place orders. And there are also many foreign friends who came for sight seeing, or entrust us to buy other stuff for them. You are most welcome to come to China, to our city and to our factory!