China High Quality Capacitance Meter Circuit Suppliers – PD free Variable Frequency Test System – HV Hipot
China High Quality Capacitance Meter Circuit Suppliers – PD free Variable Frequency Test System – HV Hipot Detail:
GDYT-350kVA/70kV PD free Resonant Test System is composed of PD free variable frequency power supply, HV measuring box, excitation transformer, isolation transformer, Resonant reactor, and capacitive voltage divider.
This test system does not have the problem of excessive starting current. Using a smaller capacity power supply can complete a test equivalent to 30 to 60 times of the power supply, which greatly alleviates the problem of insufficient capacity of the field test power supply.
Features
● Safety and reliable. It has many functions, including discharge and breakdown protection, over-voltage and over-current setting protection, test power off protection, zero protection, over-heat protection etc. When any protection happened, the system will immediately cut off output and power, to ensure the safety of operators, test system and test object.
● Simple operation and easy wiring.
● 320*240 LCD display, display output voltage, output current, frequency, environmental temperature, output waveform, date, timing etc.
● Automatic searching resonant frequency, automatic frequency setting.
● Test voltage and time can be set.
● Output sine wave distortion rate of HV circuit is lower than 1%, which is no damage to test object.
● Use indoor or outdoor. With hooks, suitable for hoisting on-site.
General Use Condition
● Altitude: ≤ 3000m.
● Environment temperature: -10℃ to 40℃.
● Storage temperature: -20℃ to 50℃
● Sunlight Strength: 0.1W/cm2 (wind speed 0.5m/s)
● Max. Daily temperature difference: 25℃.
● Using in no conductive dust, no-fire and no-explosion, corrosive free place.
● Use in outdoor or indoor. Indoor storage.
● Reliable grounding terminal should be available, earth resistance <0.5Ω
● The installation gradient of reactor should be no more than 5°.
Product detail pictures:
Related Product Guide:
All we do is usually connected with our tenet " Consumer initial, Rely on 1st, devoting around the food stuff packaging and environmental safety for China High Quality Capacitance Meter Circuit Suppliers – PD free Variable Frequency Test System – HV Hipot , The product will supply to all over the world, such as: UAE, Iran, Sydney, As a way to make use of the resource on the expanding information and facts in international trade, we welcome prospects from everywhere on the web and offline. In spite in the top quality products and solutions we supply, effective and satisfying consultation service is supplied by our professional after-sale service group. Solution lists and thorough parameters and any other info weil be sent for you timely for the inquiries. So make sure you get in touch with us by sending us emails or contact us if you have any concerns about our firm. ou can also get our address info from our web site and come to our enterprise. or a field survey of our solutions. We're confident that we have been going to share mutual results and build solid co-operation relations with our companions in this market. We're looking forward to your inquiries.