China High Quality Capacitance Meter Factories – AC Dielectric Test Equipment with manual control unit GDYD-M – HV Hipot
China High Quality Capacitance Meter Factories – AC Dielectric Test Equipment with manual control unit GDYD-M – HV Hipot Detail:
Application
AC Hipot testing is the effective and direct way to test insulation strength for electric equipment, apparatus, or machines. It checks dangerous flaws which assure electric equipment continuous working. Typical applications include testing of transformers, switchgear, cables, capacitors, aerial motors platforms, hot sticks bucket bricks, vacuum bottles and other related equipment like vacuum interrupters, blankets, ropes, gloves, hydraulics hose, instruments transformers generators.
Features
● Pointer display panel mounted controls & indicators with easy-to-read legend.
● Monitoring high voltage side voltage, low voltage side current and indicator of zero, power, working start, timing.
● Over-current protection, zero-starting protection, sound, and light alarm.
● Continuously variable output from zero to full voltage.
● Adjustable over current protection, with trip levels variable from 10 to 110%.
● With new type time relay, time range is wider (1S ~ 99H).
● Using the latest current relay, more accurate and reliable.
● Light weight, small size, easy to move.
Technical Specifications
● Input voltage: AC 220V or 380V
● Output voltage of control unit: AC 0-250V or 0-430V
● Output current of control unit:0-5/10/15/50A(customized)
● Capacity: 0-3/5/10/15/20/30/50/100kVA(customized)
● Output voltage of HV unit: 0-50/100/150/200kV(customized)
● Output current of HV unit: 0-50/100/150/200/500/1000/2000mA(customized)
● Timing: 0-9999s
● Environmental temperature: -20℃–50℃
● Voltage accuracy: ≤ 1.5%±1digit (F.S)
● Current accuracy: ≤ 1.5%±1digit (F.S)
Other accessories for option
● AC Digital Voltage Meter: 50,100,150, 200kV
● Sphere Gap
● Discharge stick
● Water resistor or solid protective resistor
● HV filter capacitor: 0.01μF-0.1μF, 40-300kV
We can customize different ratings based on different requirement. Welcome to consult with us!
Product detail pictures:
Related Product Guide:
We constantly function like a tangible group to ensure that we can give you the very best high-quality and also the very best cost for China High Quality Capacitance Meter Factories – AC Dielectric Test Equipment with manual control unit GDYD-M – HV Hipot , The product will supply to all over the world, such as: Johor, Romania, Iceland, Insisting on the high quality generation line management and customers expert assistance, we now have designed our resolution to offer our buyers using the to start with amount getting and just after services practical experience. Maintaining the prevailing friendly relations with our buyers, we however innovate our solution lists all of the time to satisfy the brand new demands and adhere to the most up-to-date development of the market in Malta. We are ready to face the worries and make the improve to understand all the possibilities in international trade.