China High Quality Capacitor Is Measured In Factory – Partial Discharge Test System GDYT series – HV Hipot
China High Quality Capacitor Is Measured In Factory – Partial Discharge Test System GDYT series – HV Hipot Detail:
GDYT is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power supply for testing object such as transformer, mutual inductor and lightning arresters. It widely used in electrical manufacturing, power operation departments, research institutes and universities.
It includes below components
1. Hipot Test Control Unit GDYD
2. PD-free Gas type transformer YDQW
3. Coupling capacitor
4. Protective resistor
5. Isolation filter LBQ
6. Partial discharge detector
Features
● Advanced PD-free epoxy insulating tube, small partial discharge capacity.
● Low impedance voltage, better than national standard.
● Automatic control technology, good anti-interference performance.
● Rapid electronic protection, high reliability.
Specifications
● Rated Capacity (KVA) : 5~5500
● High Voltage (KV): 50~250
● Low Voltage (KV): 0.22/0.38~0.38/0.6~0.6/3~3/6/10
● Top cover(mm): accordance with specific conditions
Model | Rated Capacity | High Voltage | Low Voltage | Top cover OD x Height | Weight |
(KVA) | (KV) | (KV) | (mm) | (KG) | |
GDYT-5/50 | 5 | 50 | 0.22/0.38 | 320×450 | 42 |
GDYT-50/50 | 50 | 50 | 0.22/0.38 | 850×945 | 360 |
GDYT-10/100 | 10 | 100 | 0.22/0.38 | 570×725 | 150 |
GDYT-50/100 | 50 | 100 | 0.22/0.38 | 850×1000 | 400 |
GDYT-100/100 | 100 | 100 | 0.22/0.38 | 850×1000 | 800 |
GDYT-15/150 | 15 | 150 | 0.22/0.38 | 1165×1400 | 500 |
GDYT-75/150 | 75 | 150 | 0.22/0.38 | 1350×1570 | 1100 |
GDYT-150/150 | 150 | 150 | 0.38/0.6 | 1350×1570 | 1400 |
GDYT-20/200 | 20 | 200 | 0.22/0.38 | 1165×1850 | 760 |
GDYT-100/200 | 100 | 200 | 0.22/0.38 | 1450×1950 | 1800 |
GDYT-200/200 | 200 | 200 | 0.38/0.6 | 1800×1950 | 3100 |
GDYT-25/250 | 25 | 250 | 0.22/0.38 | 1250×2200 | 1250 |
GDYT-150/250 | 150 | 250 | 0.38/0.6 | 1450×2200 | 1900 |
GDYT-250/250 | 250 | 250 | 0.38/0.6 | 2000×2300 | 3100 |
GDYT-500/250 | 500 | 250 | 3/6 | 200×2600 | 5800 |
GDYT-1000/250 | 1000 | 250 | 3/6 | 2200×2600 | 8200 |
Product detail pictures:
Related Product Guide:
With this motto in mind, we've got become among essentially the most technologically innovative, cost-efficient, and price-competitive manufacturers for China High Quality Capacitor Is Measured In Factory – Partial Discharge Test System GDYT series – HV Hipot , The product will supply to all over the world, such as: Birmingham, Rotterdam, Australia, We also provide OEM service that caters to your specific needs and requirements. With a strong team of experienced engineers in hose design and development, we value every opportunity to provide best products and solutions for our customers.