The performance of the conductive circuit of the circuit breaker is important to ensure the safe operation of the switch. The pros and cons of the conductive performance can be reflected by the size of the resistance of the conductive loop. Therefore, the IEC standard and the manufacturer have stipulated that the loop resistance should be measured, and there are clear specifications for the loop resistance of various types of switches. The loop resistance tester is a testing instrument meets the requirements of GB50150-2006 and DL / T 845.4-2004 regulations. It is widely applicable to the measurement of contact resistance, loop resistance, cable, wire, and weld contact resistance of various electrical switches.
Application
● High,middle and low voltage circuit breakers
● High,middle and low voltage disconnecting switches
● High-current bus bar joints
● Cable & Welding joints
It is suitable for high current, micro ohm measuremen
Features

Specifications
| Power supply | AC220V±10%, 50Hz |
| Power consumption | ≤500W |
| Working mode | Output time can be set. |
| Test current | 50A, 100A |
| Measurement range | 1-1999.9μΩ, resolution 0.01μΩ |
| Accuracy | 1%±0.5μΩ |
| Constant source output voltage | ≤ 5V |
| Working temperature | -20℃~40℃ |
| Relative humidity | ≤ 80%RH (no condensate) |
| Weight | 5kg |
Accessories
| Contact resistance tester | 1 set |
| Test lead | 2 pieces |
| Power cord | 2 piece |
| Fuse | 2 pieces |
| Printer paper | 2 rolls |
| Standard resistor | 1 piece |
| Ground wire | 1 piece |
| User’s manual | 1 copy |
| Test report | 1 copy |
| QC pass | 1 copy |
| Packing list | 1 copy |
Product detail pictures:
Related Product Guide:
We pursue the management tenet of "Quality is superior, Service is supreme, Reputation is first", and will sincerely create and share success with all clients for China High Quality Circuit Breaker Timing Test Factories – GDHL-100B Contact Resistance Tester (Microhm Meter) – HV Hipot , The product will supply to all over the world, such as: Egypt, Irish, Boston, By adhering to the principle of "human oriented, winning by quality", our company sincerely welcomes merchants from at home and abroad to visit us, talk business with us and jointly create a brilliant future.