China High Quality Dc Hipot Test Set Factories – DC High Voltage Generator GDZG-300 – HV Hipot
China High Quality Dc Hipot Test Set Factories – DC High Voltage Generator GDZG-300 – HV Hipot Detail:
Features
● Simple operation and complete function, easy for wild work.
● Higher voltage stability, smaller ripple coefficient.
● More reliable and stable, continuous short-circuit discharge directly to ground.
● Intelligent grounding protection and alarm function. High precision, accurate measurement, digital display of voltmeter and ammeter, with voltage resolution 0.1kV, and current 0.1uA.
● High stability of voltage regulation, smooth voltage boosting process, high adjustable precision, with coarse and fine adjustment functions. Accuracy of voltage regulation better than 0.1%, voltage and current measurement error is less than 1.0%, ripple factor better than 0.5%.
● With function of high-accuracy 75%VDC-1mA, more convenient for zinc oxide lighting arrester DC testing.
● HV booster is small size and large capacity, with △-Y shoring in the packing, which is portable to carry.
Specifications
|
Rated voltage |
40kV/60kV/120kV/200kV/300kV/500kV |
|
Rated current |
2mA/3m A/4mA/5mA/10mA |
|
Power supply |
AC 220V±10%, 50Hz |
|
Ripple coefficient |
≤1.0% |
|
Voltage meter precision |
± (1.0 %reading±2 digit) |
|
Current meter precision |
± (1.0 %reading±2 digit) |
|
Voltage stabilization |
Stochastic wave, ≤1% when power wave±10% |
|
Environment temperature |
-10 ~ 40℃ |
|
Relative humidity |
≤85% (no condensate) |
Product detail pictures:
Related Product Guide:
As for competitive selling prices, we believe that you will be searching far and wide for anything that can beat us. We will state with absolute certainty that for such excellent at such charges we are the lowest around for China High Quality Dc Hipot Test Set Factories – DC High Voltage Generator GDZG-300 – HV Hipot , The product will supply to all over the world, such as: UK, Algeria, Jordan, With the development and enlargement of mass clients abroad, now we've set up cooperative relationships with many major brands. We've our own factory and also have many reliable and well-cooperated factories in the field. Adhering to the "quality first, customer first, We are provideing high-quality, low-cost items and first-class service to customers. We sincerely hope to establish business relationship with customers from all over the world on the basis of quality, mutually benefit. We welcome OEM projects and designs.