Our firm sticks on the theory of "Quality will be the life in the enterprise, and status could be the soul of it" for Capacitor Measurement, Pd Monitoring System, Pure Wave Generator, Besides, our company sticks to high quality and reasonable price, and we also offer good OEM services to many famous brands.
China High Quality Dc Tester Exporters – High voltage divider GDFR-D1 – HV Hipot Detail:

GDFR-D1 series AC/DC Voltage Meter

GDFR-D1 series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. The digital meter and divider are equipped in one unit. 

Features

● Balance type equal potential shield structure.
● Fully-sealed insulation cylinder with internal excellent components.
● High accuracy and linearity, good stability and anti-interference ability.
● With good filling materials, which make the structure smaller and weight lighter, and minimize internal partial discharge.
● Small size, light weight, easy to carry in the field work.
● Inner shield anti-interference system.
● The voltage ratio can be customized, suitable for calibration.
● External voltage meter can be connected.

Technical Specifications

Model No. GDFR-D1-50 GDFR-D1-100 GDFR-D1-150 GDFR-D1-200 GDFR-D1-300 GDFR-D1-400
Voltage(kV) 50 100 150 200 300 400
DC frequency(Hz) <2
AC frequency(Hz) 30-300
Accuracy
(G type)
AC: 1.0%/DC: 0.5% –
Accuracy
(H type)
AC: 0.5%/DC: 0.5% – –
Impedance
(MΩ)
650 1280 2000 2640 4000 5360
Capacitance
(pF)
500 250 400/160 300 200 300
Voltage ratio 1000:1 or 10000:1(or customized)
Height (mm) 500 650 900 1200 1750 2350
Dimension
(mm)
150×150 160×160 200×200 260×260 800×800
Cable impedance(Ω) 50 / 75
Range 1. Low range: 0-20kV
2. High range: 20kV-rated voltage
1. Low range: 0-200kV
2. High range: 200kV-rated voltage
Cable length(m) 3 4 5 6 8 10
Weight(kg) 5.5 6.9 10.6 14.1 23.5 48.2
Packing Medium Imported dry type high polymer materials
Operation temperature 0℃-45℃
Relative humidity <85%RH, no condensation
Altitude <1500m(or customized)
Use condition Indoor use or outdoor use in Sunny day

Product detail pictures:

China High Quality Dc Tester Exporters –  High voltage divider GDFR-D1 – HV Hipot detail pictures


Related Product Guide:

We consistently carry out our spirit of ''Innovation bringing development, Highly-quality ensuring subsistence, Management promoting benefit, Credit attracting customers for China High Quality Dc Tester Exporters – High voltage divider GDFR-D1 – HV Hipot , The product will supply to all over the world, such as: Guatemala, Sao Paulo, Liverpool, Our technical expertise, customer-friendly service, and specialized products make us/company name the first choice of customers and vendors. We are looking for your inquiry. Let's set up the cooperation right now!
  • This manufacturers not only respected our choice and requirements, but also gave us a lot of good suggestions, ultimately, we successfully completed the procurement tasks.
    5 Stars By Dora from Oman - 2018.09.19 18:37
    This is the first business after our company establish, products and services are very satisfying, we have a good start, we hope to cooperate continuous in the future!
    5 Stars By June from Morocco - 2017.10.13 10:47

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us