China High Quality dew point analyzer Manufacturer – GDZL-503 Automatic Interfacial Tension tester – HV Hipot
China High Quality dew point analyzer Manufacturer – GDZL-503 Automatic Interfacial Tension tester – HV Hipot Detail:
Intermolecular forces will generate interface tension and surface tension of liquids. The value of tension reflects liquid sample’s physics and chemical properties, which is one of the most important index for product quality.
GDZL-503 automatic interfacial tension tester tests kinds of liquid surface tension and interface tension according to ring method which is simple and accurate. It is widely used in electric, petroleum, chemical,medicine, food and teaching filed.
Features
● Exclusive and quick response electromagnetic balance sensor is adopted, to improve the accuracy of the measurement and degree of linearity.
● Only using one point calibration, to solve the problem of previous sensor which needs multi-point calibration. It is no need to use zero potentiometer and full scale potentiometer.
● Real-time show equivalent tension value and current weight.
● Integrated with temperature detection circuit, to compensate temperature automatically for test result.
● 240*128 dot matrix LCD screen.No logo button has function of screen protection.
● Save up to 255 history records with time indicated.
● Built in high speed thermal mini printer to print out quickly. It also has function of offline print.
● With RS232 port, to connect with PC directly.
Specification
| Measuring range | 0-200mN/m |
| Accuracy | 0.1% of the reading±0.1 mN/m |
| Resolution | 0.1mN/m |
| Sensitivity | 0.1mN/m |
| Power supply | AC220V±20%,50Hz±10% |
| Maximum power consumption | 20W |
| Environmental temperature | 10~30℃(25℃ is the best) |
| Environmental humidity | ≤85% RH |
| Dimension | 200×300×330(mm) |
| Weight | 6kg |
Product detail pictures:
Related Product Guide:
We now have a highly efficient crew to deal with inquiries from clients. Our intention is "100% shopper pleasure by our merchandise quality, price tag & our staff service" and take pleasure in a very good standing amongst purchasers. With quite a few factories, we can easily provide a wide vary of China High Quality dew point analyzer Manufacturer – GDZL-503 Automatic Interfacial Tension tester – HV Hipot , The product will supply to all over the world, such as: Mexico, Myanmar, Dominica, We have gained a lot of recognition among customers spread all across the world. They trust us and always give repetitive orders. Furthermore, mentioned below are some of the major factors that have played significant role in our tremendous growth in this domain.
Product quality is good, quality assurance system is complete, every link can inquire and solve the problem timely!





