China High Quality digital earth resistance tester price Exporters – GDCR3000 Digital Earth Resistance Tester – HV Hipot

China High Quality digital earth resistance tester price Exporters – GDCR3000 Digital Earth Resistance Tester – HV Hipot

Brief Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our enhancement depends around the sophisticated devices ,exceptional talents and repeatedly strengthened technology forces for Capacitance Measuring Instrument, Winding Resistance Measurement Of Transformer, Surge Voltage Test, We guaranteed quality, if customers were not satisfied with the products' quality, you can return within 7days with their original states.
China High Quality digital earth resistance tester price Exporters – GDCR3000 Digital Earth Resistance Tester – HV Hipot Detail:

General Information

GDCR3000 Digital Earth Resistance Tester is specially designed and manufactured for field measurement, adopting the latest digital and micro-processing technology, 3-pole or 2-pole method for earth resistance measurement, with a unique function of wire resistance verification, anti-interference capability and the ability to adapt to the environment, to ensure high precision, high stability and reliability for prolonged measure, which is widely used in electric power, telecommunications, meteorology, oil field, construction, lightning protection, industrial electrical equipment and other earth ground resistance measurement.

Measurement range & Accuracy

Measurement function Range Accuracy Resolution
Earth resistance 0.01Ω~20Ω ±2%rdg ±3dgt (Auxiliary earth resistance 100Ω±5% , earth voltage <10V) 0.01Ω
0.1Ω~200Ω 0.1Ω
1Ω~2000Ω 1Ω
Earth voltage 0~600V  AC ±1%rdg ±3dgt 1V

Specifications

Function Earth ground resistance measurement, voltage to ground measurement, low value resistance measurement
Power Supply DC 9V(Zi-Mn dry battery R14S 1.5V 6 PCS)
Backlight Controllable blue backlight, suitable for use in dark place.  
Measuring Mode Precise 3-pole measurement, simple 2-pole measurement
Measuring Method Earth ground resistance: rated current change-pole method, measurement current 20mA Max.
Voltage to ground: average value rectification
Data Mode Average value, maximum, minimum
Wire Resistance Verification Avoid error caused by testing wire that is failed to be fully inserted into tester interface or by poor contact or by users’ replacing or lengthening testing wires, making it more accurate for earth ground resistance measurement.
Display Mode 4-digital super-large LCD display, blue screen backlight
Measuring indicator During measurement, LED flash indicator, LCD count down display
LCD Dimension 128mm×75mm; Display field:124mm×67mm
Dimension L×W×H: 215mm×190mm×95mm
Testing Wires Three wires: each for Red 20m, Yellow 10m, and Green 5m
Simple Testing Wire 2 wires: each for Red 1.6m and Green 1.6m
Auxiliary earthing rod 2 PCS: Φ10mm×150mm
Measuring Rate Voltage to ground: about 3 times/second; earth ground resistance: about 5 seconds/time
Measuring Times Over 5000 times
(Measuring 10Ω for one time on 20Ω range and take a pause for 30s)
Circuit Voltage Measuring voltage to ground: measuring below AC 600V
USB Interface Possess USB interface, software supervision, storage data can be uploaded to computer, saved or printed.
Communication Wire One piece of USB communication wire, with length 1.5m
Data Storage 400 sets, flash display “FULL” icon to indicate storage is full
Data Hold Data hold function: “HOLD” icon display
Data Read Data read function: “READ” icon display
Overflow Display Exceeding measuring range overflow function: “O” icon display
Alarm Function When measuring value exceeds alarm setting value, there is “Toot-toot-toot” alarm hint
Battery Voltage When battery voltage decreases to about 7.8V, battery voltage low icon will display, reminding to charge.  
Power Consumption Backlight: 25mA Max
Standby: 25mA Max(Backlight shut off)
Measurement:200mA Max(Backlight shut off)
Weight Tester:1325g(including battery)
Testing Wires: 847g(including simply testing wires)
Auxiliary earthing rod: 468g (2 PCS)
Meter bag: 915g
Working Temperature & Humidity -10℃~40℃; below 80%rh
Storage temperature  & humidity -20℃~60℃; below 70%rh
Overload Protection Measuring earth ground resistance: between each interfaces of E-P, E-C, AC 280V/3 seconds
Insulation Resistance Over 10MΩ(between circuit and enclosure it is 500V)
Withstanding Voltage AC 3700V/rms (Between circuit and enclosure)
Electromagnetic Features Wireless frequency electromagnetic field
Protection Type IEC61010-1, IEC1010-2-31, IEC61557-1,5, IEC60529(IP54), Pollution etc. 2, CAT Ⅲ 300V

Product detail pictures:

China High Quality digital earth resistance tester price Exporters –  GDCR3000 Digital Earth Resistance Tester – HV Hipot detail pictures

China High Quality digital earth resistance tester price Exporters –  GDCR3000 Digital Earth Resistance Tester – HV Hipot detail pictures

China High Quality digital earth resistance tester price Exporters –  GDCR3000 Digital Earth Resistance Tester – HV Hipot detail pictures

China High Quality digital earth resistance tester price Exporters –  GDCR3000 Digital Earth Resistance Tester – HV Hipot detail pictures

China High Quality digital earth resistance tester price Exporters –  GDCR3000 Digital Earth Resistance Tester – HV Hipot detail pictures

China High Quality digital earth resistance tester price Exporters –  GDCR3000 Digital Earth Resistance Tester – HV Hipot detail pictures


Related Product Guide:

The really abundant projects administration experiences and just one to one particular provider model make the substantial importance of organization communication and our easy understanding of your expectations for China High Quality digital earth resistance tester price Exporters – GDCR3000 Digital Earth Resistance Tester – HV Hipot , The product will supply to all over the world, such as: Iraq, Serbia, Kuwait, Our expert engineering team will generally be prepared to serve you for consultation and feedback. We are able to also offer you with free of charge samples to meet your requirements. Best efforts will likely be produced to provide you the best service and merchandise. When you are keen on our business and products, please speak to us by sending us emails or call us quickly. In an effort to know our products and company extra, you may come to our factory to view it. We will generally welcome guests from all over the world to our business to create business relations with us. Please feel cost-free to speak to us for small business and we believe we'll share the best trading experience with all our merchants.
  • The product manager is a very hot and professional person, we have a pleasant conversation, and finally we reached a consensus agreement.
    5 Stars By Mary from Amsterdam - 2018.07.12 12:19
    The customer service reprersentative explained very detailed, service attitude is very good, reply is very timely and comprehensive, a happy communication! We hope to have a opportunity to cooperate.
    5 Stars By Murray from Russia - 2017.08.15 12:36

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us