China High Quality energy meter calibration equipment Suppliers – GDYM-3M Multi-functional Electric Energy Meter Calibrator – HV Hipot
China High Quality energy meter calibration equipment Suppliers – GDYM-3M Multi-functional Electric Energy Meter Calibrator – HV Hipot Detail:
Features
Latest features
1. 32-bit high speed digital signal processor
Using 32-bit high speed 120MHz DPS of TI, and high performance 16-bit AD with 6 channels. The digital multiplier units with multiple functions and wide range of measurement was successfully developed by means of floating point computations.Therefore, the calculating accuracy can be guaranteed.
2. Wring simulation function
The various wiring methods can be simulated and obtain their corresponding results in office by the calibrator without connecting voltage or current signals.This function will be used as training materials and tools for training line inspection skills. Enable to greatly improve the inspection skills for on-site working staffs.
3. Error self-checking for 5A clamp
The 5A and 0.5A current signal will be generated and output to 5A and 100A clamp, in order to measure errors of the clamp. It solved error variation problem of 5A and 100A clamp after long time use, enabling the operator to understand the closure status of the clamp and remind staffs to clear the clamp jaw in time.
4. Super wide current measurement range
Up to 500 times current measurement range to ensure the measurement index. Up to 10000 times current display range. The minimum starting current is 1mA. Wiring can be identified even in No-load condition.
5. Accumulative function for electronic energy
To calibrate energy meter without electronic energy pulse output. Or it can be considered as the index of energy saving test.
6. Wireless inspection
Comprehensive inspection for the faults of on-site measuring system, checking the composite error of high voltage and low voltage.
Other features
1. Using 4.7 inches 16:9 TFT LCD screen, clear and good performance, high resolution, abundant information and rich content. Each function of the calibrator is displayed on one screen, no need to flip the screen to see all parameters of each function. It makes users absolutely clear about the calibrator during using..
2. The errors, voltage, current, active and reactive power, phase, frequency, and power factor can be measured simultaneously, also vector figure and wiring results will be displayed.
3. Without any adjustable resistor in the calibrator, all errors will be modified by software.
4. The ratio of the low voltage CT can be measured directly with 5A,100A, 500A, 1000A clamp. All faults, such as disconnection, poor connection of the secondary circuit of CT, short circuit of turns within CT, and CT nameplate ratio is consistent with CT actual turns ratio or not, etc. will be discovered.
5. Voltage and current harmonic from 2 to 21 times of A, B, C phase can be real-time measured to know the electricity quality of power grid.
6. The wave form of A, B, C three-phase voltage or current can be measured and displayed.
7. Wide supply voltage range from 45V to 480V.
8. All on-site input parameters and data can be user-defined. 1000 user’s data can be downloaded.
Special Features
● The calibrator will alarm by sound and light when supplying 380V to voltage test line.
● When the simulation load current line is wrong connected to the neutral line of the meter, the first automatic protection will not output current. When making the fault connection again, the secondary protective fuse will be burn out, which applies absolutely protection. The calibrator will recover after replacing the fuse.
● The fuse will be burn out when the impulse line hit 220V, the calibrator will recover after replacing the fuse.
Specifications
Voltage Range | 30V-480V | 5A Clamp | Active power energy,power | ±0.5% | |
Voltage Error | ±0.2% | Reactive power energy, power | ±0.5% | ||
Clamp (1times over-load) | 5A,100A,500A,1000A | Current | ±0.5% | ||
Input Frequency Range | 45-55Hz | Self-checking Current | 5A 0.5A | ||
Frequency Measurement Error | ±0.01Hz | Self-checking Error | ±0.1% | ||
Phase Measurement Range | -180°~ +180° | Big Current Clamp | Active power energy, power | ±0.5% | |
Maximum Phase Error | ±0.1° | Reactive power energy, power | ±0.5% | ||
Harmonic Measurement | ±0.1% | Current | ±0.5% | ||
Harmonic Measurement Range | 2-51times | Others | Ratio Measurement | ±0.5% | |
Current Terminal | Active power energy | ±0.1% | Voltage Influence | < ±0.01% | |
Reactive power energy | ±0.5% | Frequency Influence | < ±0.01% | ||
Low Frequency Pulse Constant | 5A | 3600P/kWh | Temperature Influence | < ±0.005%/ºC | |
Others | 3600*(5/Ie) | 24hours change error | < ±0.04% | ||
P/kWh | |||||
Harmonic Influence | < ±0.01% | ||||
Note: Ie is rated current | Standby time after start-up | ||||
Power Supply | AC 45V - 480V | Environmental temperature | -25ºC- +45ºC | ||
Power Consumption | < 10W | Relative humidity | 40%-95% | ||
Dimension | 214mm * 158mm *71mm | Continuous working time of the battery | >8hours | ||
Weight | < 1.2 kg | Battery charge voltage | DC 12V |
Accessories
GDYM-3M Calibrator | 1 set |
100A clamp meter | 3 pieces |
Correction ring | 1 piece |
Management Software (CD-ROM) | 1 piece |
Test lead | 1 piece |
Electronic meter pulse line | 1 piece |
Power cable | 1 piece |
232 communication line | 1 piece |
Photoelectric head | 1 piece |
Adapter | 1 piece |
Instrument case | 1 piece |
Manual | 1 copy |
Product detail pictures:
Related Product Guide:
To be a result of ours specialty and service consciousness, our enterprise has won an excellent status between buyers all around the globe for China High Quality energy meter calibration equipment Suppliers – GDYM-3M Multi-functional Electric Energy Meter Calibrator – HV Hipot , The product will supply to all over the world, such as: Johannesburg, El Salvador, Anguilla, For more than ten years experience in this filed, our company has gained high reputation from home and abroad. So we welcome friends from all over the world to come and contact us, not only for business, but also for friendship.
By Hedda from Turkey - 2018.12.22 12:52
Production management mechanism is completed, quality is guaranteed, high credibility and service let the cooperation is easy, perfect!
By Alma from Norwegian - 2018.09.16 11:31