China High Quality grounding resistance Suppliers – GD2000H 10kV Insulation Resistance Tester – HV Hipot
China High Quality grounding resistance Suppliers – GD2000H 10kV Insulation Resistance Tester – HV Hipot Detail:
General Information
This device can test insulation resistance (such as transformer, switchgear, leads, motor) of different modules in one system, to insulate and repair failure components.
It is important to ensure products quality and security of person and equipment during operation by insulation test of checking test object to ground or adjacent conductors’ insulation.
Before power on the system, use insulation test to verify if it is good to improve system performance. Insulation test is to find manufacturing process problems and equipment fault which can’t be found before failure happened. In EU, this test is compulsory, even to civil system.
Features
1. Voltage output GD2000H (5kV/10kV).Resistance range 0-400GΩ.
2. Two modes display insulation resistance.
3. Auto-calculating absorption ratio and polarization index.
4. Friendly operation, continuous saving 19times measurement results.
5. Auto-discharge residual high voltage after test is over.
6. AC/DC power supply, with rechargeable battery or AC adapter.
7. Strong anti-interference ability, stable and reliable reading.
8. Portable design, suitable for wild work.
9. Short-circuit current ≥3.5mA, ideal equipment for testing insulation resistance of large transformer, inductor, generator, HV motors, electric capacitor, cables and surge arrester.
Technical Specifications
|
Item Model |
GD2000H |
||
|
Output voltage |
5kV DC |
10kV DC |
|
|
Accuracy |
Temperature |
23℃±5℃ |
|
|
Insulation resistance |
5M ~ 100G ±5% |
10M ~ 200G ±5% |
|
|
Other range: ±10% |
|||
|
Output voltage |
40M ~ 200G 0 ~ +10% |
80M-400GΩ 0 –+10% |
|
|
Short-circuit current |
≥3.5mA |
||
|
Power supply |
8 * AA type high capacity rechargeable battery & external adapter |
||
|
Working Temp.& Humidity |
-10℃–40℃,max.relative humidity 85% |
||
|
Storage Temp.& Humidity |
-20℃–60℃,max.relative humidity 90% |
||
|
Insulation |
Max.20000MΩ when voltage between circuit and shell is 1000VDC. |
||
|
Withstand voltage |
Withstand 1min when voltage between circuit and shell is 3kV /50Hz AC |
||
|
Dimension |
230mm*190mm*90mm (L*W*H) |
||
|
Weight |
3kg |
||
|
Accessories |
Test leads, manual, rechargeable adapter, power cable, test report |
||
Accessories
| Insulation resistance tester | 1set |
| Test wire | 1piece |
| Power adapter | 1piece |
| Power cord | 1piece |
| User’s Guide | 1copy |
| Certificate | 1copy |
Product detail pictures:
Related Product Guide:
Persisting in "High high quality, Prompt Delivery, Aggressive Price", we've established long-term cooperation with clients from the two overseas and domestically and get new and old clients' superior comments for China High Quality grounding resistance Suppliers – GD2000H 10kV Insulation Resistance Tester – HV Hipot , The product will supply to all over the world, such as: Bangladesh, Ottawa, Algeria, We have more than 10 years exported experience and our products have expored more than 30 countries around the word . We always hold the service tenet Client first,Quality first in our mind,and are strict with product quality. Welcome your visiting!
The company leader recept us warmly, through a meticulous and thorough discussion, we signed a purchase order. Hope to cooperate smoothly