China High Quality high voltage test kit Manufacturers – High voltage divider GDFR-D1 – HV Hipot
China High Quality high voltage test kit Manufacturers – High voltage divider GDFR-D1 – HV Hipot Detail:
GDFR-D1 series AC/DC Voltage Meter
GDFR-D1 series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. The digital meter and divider are equipped in one unit.
Features
● Balance type equal potential shield structure.
● Fully-sealed insulation cylinder with internal excellent components.
● High accuracy and linearity, good stability and anti-interference ability.
● With good filling materials, which make the structure smaller and weight lighter, and minimize internal partial discharge.
● Small size, light weight, easy to carry in the field work.
● Inner shield anti-interference system.
● The voltage ratio can be customized, suitable for calibration.
● External voltage meter can be connected.
Technical Specifications
| Model No. | GDFR-D1-50 | GDFR-D1-100 | GDFR-D1-150 | GDFR-D1-200 | GDFR-D1-300 | GDFR-D1-400 | |
| Voltage(kV) | 50 | 100 | 150 | 200 | 300 | 400 | |
| DC frequency(Hz) | <2 | ||||||
| AC frequency(Hz) | 30-300 | ||||||
| Accuracy (G type) |
AC: 1.0%/DC: 0.5% | – | |||||
| Accuracy (H type) |
AC: 0.5%/DC: 0.5% | – | – | ||||
| Impedance (MΩ) |
650 | 1280 | 2000 | 2640 | 4000 | 5360 | |
| Capacitance (pF) |
500 | 250 | 400/160 | 300 | 200 | 300 | |
| Voltage ratio | 1000:1 or 10000:1(or customized) | ||||||
| Height (mm) | 500 | 650 | 900 | 1200 | 1750 | 2350 | |
| Dimension (mm) |
150×150 | 160×160 | 200×200 | 260×260 | 800×800 | ||
| Cable impedance(Ω) | 50 / 75 | ||||||
| Range | 1. Low range: 0-20kV 2. High range: 20kV-rated voltage |
1. Low range: 0-200kV 2. High range: 200kV-rated voltage |
|||||
| Cable length(m) | 3 | 4 | 5 | 6 | 8 | 10 | |
| Weight(kg) | 5.5 | 6.9 | 10.6 | 14.1 | 23.5 | 48.2 | |
| Packing Medium | Imported dry type high polymer materials | ||||||
| Operation temperature | 0℃-45℃ | ||||||
| Relative humidity | <85%RH, no condensation | ||||||
| Altitude | <1500m(or customized) | ||||||
| Use condition | Indoor use or outdoor use in Sunny day | ||||||
Product detail pictures:
Related Product Guide:
abide by the contract", conforms on the market requirement, joins from the market competition by its good quality likewise as provides more comprehensive and superb support for customers to let them become large winner. The pursue of the company, is definitely the clients' pleasure for China High Quality high voltage test kit Manufacturers – High voltage divider GDFR-D1 – HV Hipot , The product will supply to all over the world, such as: Guatemala, Croatia, Georgia, If you are for any reason unsure which product to select, do not hesitate to contact us and we are going to be delighted to advise and assist you. This way we are going to be providing you with all the knowledge needed to make the best choice. Our company strictly follows "Survive by good quality, Develop by keeping good credit. " operation policy. Welcome all the clients old and new to visit our company and talk about the business. We have been looking for more and more customers to create the glorious future.