Normally customer-oriented, and it's our ultimate concentrate on for being not only one of the most dependable, trustable and honest supplier, but also the partner for our shoppers for Winding Resistance Test Of Motor, Online Pd Testing, Dielectric Strength Testing, Our professional technological team will be wholeheartedly at your services. We sincerely welcome you to definitely take a look at our website and enterprise and send out us your inquiry.
China High Quality high voltage test kit Manufacturers – High voltage divider GDFR-D1 – HV Hipot Detail:

GDFR-D1 series AC/DC Voltage Meter

GDFR-D1 series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. The digital meter and divider are equipped in one unit. 

Features

● Balance type equal potential shield structure.
● Fully-sealed insulation cylinder with internal excellent components.
● High accuracy and linearity, good stability and anti-interference ability.
● With good filling materials, which make the structure smaller and weight lighter, and minimize internal partial discharge.
● Small size, light weight, easy to carry in the field work.
● Inner shield anti-interference system.
● The voltage ratio can be customized, suitable for calibration.
● External voltage meter can be connected.

Technical Specifications

Model No. GDFR-D1-50 GDFR-D1-100 GDFR-D1-150 GDFR-D1-200 GDFR-D1-300 GDFR-D1-400
Voltage(kV) 50 100 150 200 300 400
DC frequency(Hz) <2
AC frequency(Hz) 30-300
Accuracy
(G type)
AC: 1.0%/DC: 0.5% –
Accuracy
(H type)
AC: 0.5%/DC: 0.5% – –
Impedance
(MΩ)
650 1280 2000 2640 4000 5360
Capacitance
(pF)
500 250 400/160 300 200 300
Voltage ratio 1000:1 or 10000:1(or customized)
Height (mm) 500 650 900 1200 1750 2350
Dimension
(mm)
150×150 160×160 200×200 260×260 800×800
Cable impedance(Ω) 50 / 75
Range 1. Low range: 0-20kV
2. High range: 20kV-rated voltage
1. Low range: 0-200kV
2. High range: 200kV-rated voltage
Cable length(m) 3 4 5 6 8 10
Weight(kg) 5.5 6.9 10.6 14.1 23.5 48.2
Packing Medium Imported dry type high polymer materials
Operation temperature 0℃-45℃
Relative humidity <85%RH, no condensation
Altitude <1500m(or customized)
Use condition Indoor use or outdoor use in Sunny day

Product detail pictures:

China High Quality high voltage test kit Manufacturers –  High voltage divider GDFR-D1 – HV Hipot detail pictures


Related Product Guide:

abide by the contract", conforms on the market requirement, joins from the market competition by its good quality likewise as provides more comprehensive and superb support for customers to let them become large winner. The pursue of the company, is definitely the clients' pleasure for China High Quality high voltage test kit Manufacturers – High voltage divider GDFR-D1 – HV Hipot , The product will supply to all over the world, such as: Guatemala, Croatia, Georgia, If you are for any reason unsure which product to select, do not hesitate to contact us and we are going to be delighted to advise and assist you. This way we are going to be providing you with all the knowledge needed to make the best choice. Our company strictly follows "Survive by good quality, Develop by keeping good credit. " operation policy. Welcome all the clients old and new to visit our company and talk about the business. We have been looking for more and more customers to create the glorious future.
  • Cooperate with you every time is very successful, very happy. Hope that we can have more cooperation!
    5 Stars By Eunice from azerbaijan - 2017.08.18 11:04
    Product variety is complete, good quality and inexpensive, the delivery is fast and transport is security, very good, we are happy to cooperate with a reputable company!
    5 Stars By Erin from Amman - 2018.09.23 18:44

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us