China High Quality how to measure flash point Factories – GDBS-305 Automatic Flash Point Closed Cup Tester – HV Hipot
China High Quality how to measure flash point Factories – GDBS-305 Automatic Flash Point Closed Cup Tester – HV Hipot Detail:
General Information
GDBS-305 automatic closed cup flash point tester is the device testing closed cup flash point for petroleum products. It use module design which one host can control several testing furnace, to test different samples at the same time or separately. The testing furnace port can be connected to the host disorderly. It widely used in the field of railway, air company, power, petroleum and research department.
Features
● 320*240 TFT LCD screen.
● With high speed signal processor control, reliable and high accuracy.
● One host can control several test furnace to test several samples at one time, which will save testing time.
● Automatic ignition with no gas source ignition mode.
● Built-in atmosphere pressure sensor, auto-measure and calibrate result.
● Self-adaptive PID control calculation, automatic adjusting temperature rise curve according to standard requirements.
● Procedures including temperature rise,uncap,ignition,alarm,cooling,print are realized automatically.
● With fault auto-detection alarm function.When sensor fault,sample mistake,temperature over value,the instrument will stop automatically and alarm.
● Built-in high speed thermal printer.
● Store up to 255pcs history records.
Specifications and Attentions
● Temperature measure range: -59.9℃–299.9℃
● Temperature control range: room temperature–299.9℃
● Repeatability: 0.025X(X is average value of test result for continuous twice test)
● Resolution: 0.1℃
● Thermometric sensor: Pt resistance(A grade PT100)
● Flash fire sensor: Thermocouple
● Power voltage: AC220V±20% 50HZ±10%
● Max.Power: 400W
● Environmental temperature: 0℃-40℃
● Relative humidity: ≤85% RH
● Weight: 18kg
● Dimension: 480*260*300mm
Product detail pictures:
Related Product Guide:
We've been convinced that with joint efforts, the enterprise between us will bring us mutual benefits. We could guarantee you item excellent and aggressive price tag for China High Quality how to measure flash point Factories – GDBS-305 Automatic Flash Point Closed Cup Tester – HV Hipot , The product will supply to all over the world, such as: Saudi Arabia, Peru, Argentina, Our tenet is "integrity first, quality best". We have confidence in providing you with excellent service and ideal products. We sincerely hope we can establish win-win business cooperation with you in the future!
This is a very professional and honest Chinese supplier, from now on we fell in love with the Chinese manufacturing.





