Features
● With high speed, big capacity data acquisition card. Continuously collect partial discharge data, good repeatability, and high accuracy.
● Functions of testing, analyzing (multi-parameter analysis, two-dimension atlas analysis, three-dimension atlas analysis), data storage, report, and print. Display waveform (ellipse, sine wave, line), discharge value and test voltage.
● Suitable for 50Hz, 150Hz frequency power supply, up to 400Hz. Automatic tracking external power supply frequency.
● Big color LCD screen. Large memory, with USB port.
● With anti-false operation function. Automatic adjusting gain during testing and rectifying.
● Anti-interference design.
Specifications
● Capacitance range: 6pF-250μF
● Sensitivity: <0.02pc (capacitance at 50pF)
● Amplifier: 3db low frequency fl 10kHz, 20kHz, 30kHz, 50kHz, 80kHz. / 3db high frequency fh 100kHz, 200kHz, 300kHz, 400kHz, 500kHz.
● Gain adjustment range>120db, gain difference 20±1db, asymmetry of positive/negative pulse response<1db
● Time window: width 1°-360°, can be rotated at any time.
● Test voltage: 0-200kV, error <3% F.S.
● Acquisition channel: 4 or 6channels/card.
● Input impedance: 1MΩ.
● Max. Sampling rate: 20Mhz.
● AD resolution: 12bit, DC accuracy 0.2%.
● Sampling length of each channel: 8M.
● Triggering mode: Manual, internal triggering, external triggering.
● Bandwidth of acquisition card: 3Mhz(-3db).
● Weight: about 15kg.
Product detail pictures:
Related Product Guide:
We have been commitment to supply the competitive price ,excellent products and solutions high-quality, at the same time as fast delivery for China High Quality Ipec Partial Discharge Factories – GDJF-2006 Partial Discharge Analyzer – HV Hipot , The product will supply to all over the world, such as: Malawi, Puerto Rico, Estonia, During in 11 years, We have participated in more than 20 exhibitions, obtains the highest praise from each customer. Our company has been devoting that "customer first" and committed to helping customers expand their business, so that they become the Big Boss !