We now have many fantastic staff members customers superior at advertising, QC, and working with varieties of troublesome problem within the generation system for Power Transformer And Instrument Transformer, High Voltage Pulse Generator, Blocking Cap, Never-ending improvement and striving for 0% deficiency are our two main quality policies. Should you need anything, don't hesitate to contact us.
China High Quality ir tester Suppliers – GDHX-9700 Phase Detector – HV Hipot Detail:

General Information

GDHX-9700 Phase Detector is mainly used in electric power lines, phase, and phase sequence calibration in substation, with main functions including electrical inspection, phase calibration and phase sequence measurement. It uses double shielding and brand-new digital circuits, with strong anti-interference, accorded with EMC standards, suitable for various electromagnetic interference situations.

The high voltage phase signal of measured lead will be transmitted directly after treatment, the handset will receive and make phase comparison, determine the results after phase detection, real-time display phase angle difference and vector. It uses wireless transmission technology, safe and reliable, fast, and accurate, suitable for using at different voltage levels (10V-500KV). When checking the grid structure, it can accurately identify the relative phase of different leads for the three-phase connected line, without any electrical connection between two measurement components, which makes the application of the measurement device very flexible and safe.

Features

● Voltage range: 10V~500KV, applicable for various voltage grades.
● Accuracy: short distance: error ≤±3°; long distance: error ≤±3°.
● Sampling rate: 10 times/second.
● Date and time setting, date and time adjustment, easy for users to browse, view the historical data.
● Backlight setting: normally on, normally off, user-defined within 0~999s.
● Auto shut-down: never, user-defined within 0~999 minutes.
● In-phase: ≤20° (user-defined if phase threshold is within 0-90°, default 20°)
● Out-phase: >20° (user-defined if phase threshold is within 0-90°, default 20°)
● On-site calibration function: on-site calibration can be carried out on the tested wire to ensure the accuracy of phase angle.
● Multiple mode design, better applicability, more secure, more convenient.
● Unique human-machine interface, simple operation.
● FCC antenna design, stronger signal, easier to penetrate walls, doors, and barriers.
● Double shielding, strong anti-interference, in full compliance with EMC standards.
● Charts and data display, easier to read, with date and time display function.
● Qualitative measurement: display by acousto-optic signal.
● Quantitative measurement: real-time display of phase angle difference, error ≤5°.
● Phase sequence check: positive phase sequence, negative phase sequence (120°, 240°).
● Under GPS satellite timing service, the detection distance between detector Xa and Ya is ≥500km.
● Data storage capacity of 2000 groups. It can query and access to historical data.
● The length of standard insulation rod is 4m, and the applicable voltage grade of insulation rod is ≤ 220kV.

Technical Parameters

Voltage range

10V~500kV

Power supply

Hand-held unit: large capacity lithium battery

Xa & Ya detector: AA size alkaline battery (1.5V) 3pcs

Wireless transmission

Visual distance 150m

In-phase

≤20° (user-defined if phase threshold is within 0-90°)

Out-phase

>20° (user-defined if phase threshold is within 0-90°)

Display accuracy

Quantitative measurement ≤5°

Resolution of phase angle

1°

Phase sequence measurement

Phase sequence is determined through clockwise 120°/ counterclockwise 240°

Satellite timing range

2~30 minutes

Display

Positive type LCD screen, clear in the sunlight.

Working temperature

-35~+50℃

Storage temperature

-40~+55℃

Relative humidity

≤95%RH, condensing

Hand-held unit

0.31 kg

Detector Xa

0.16 kg

Detector Ya

0.16 kg


Product detail pictures:

China High Quality ir tester Suppliers –  GDHX-9700 Phase Detector – HV Hipot detail pictures

China High Quality ir tester Suppliers –  GDHX-9700 Phase Detector – HV Hipot detail pictures

China High Quality ir tester Suppliers –  GDHX-9700 Phase Detector – HV Hipot detail pictures


Related Product Guide:

Fast and superior quotations, informed advisers to help you choose the correct merchandise that suits all your requirements, a short generation time, responsible quality control and different services for paying and shipping affairs for China High Quality ir tester Suppliers – GDHX-9700 Phase Detector – HV Hipot , The product will supply to all over the world, such as: Buenos Aires, Uruguay, venezuela, Upon today, we've customers from all over the world, including USA, Russia, Spain, Italy, Singapore, Malaysia, Thailand, Poland, Iran and Iraq. The mission of our company is to provide the highest quality products with best price. We've been looking forward to doing business with you.
  • We have been appreciated the Chinese manufacturing, this time also did not let us disappoint,good job!
    5 Stars By Doreen from Lithuania - 2017.09.09 10:18
    The company can keep up with the changes in this industry market, product updates fast and the price is cheap, this is our second cooperation, it's good.
    5 Stars By Ann from Montreal - 2017.05.02 18:28

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us