China High Quality Meter Sf6 Leak Detection Supplier – GDP-713PM SF6 Gas Dew Point Tester (Chilled Mirror Method) – HV Hipot
China High Quality Meter Sf6 Leak Detection Supplier – GDP-713PM SF6 Gas Dew Point Tester (Chilled Mirror Method) – HV Hipot Detail:
Features
Using the principle of chilled mirror balance, there is no measurement error caused by lag, and the measurement accuracy is high.
Good repeatability, fast response, high sensitivity, and good stability.
5-inch full-color high-resolution LCD screen, which can simultaneously display instrument working parameters such as dew point, mirror light intensity, sample gas flow rate and so on. It can also convert the dew point value and the water concentration.
It has the function of testing the maximum refrigeration capacity; the low-humidity quick balance function ensures that the instrument can quickly and accurately measure the dew point.
The measuring gas circuit is easy to connect, easy to operate, and easy to carry, suitable for many occasions.
Touch screen human-computer interaction, dynamic graph curve display, easy and intuitive operation.
Abundant system function expansion, other functions can be customized according to requirements.
Specifications
Measurement method: Auto chilled mirror measurement (Peltier refrigeration)
Measurement range: -20ºC ~ +60ºC (At 20ºC atmospheric pressure)
Accuracy: ±0.1 ~ ±0.2ºC
Repeatability: ±0.05ºC
Measurement mode: Automatic
Number of refrigeration stages: Four
Auxiliary cooling: Heat pipe
Dew point temperature sensor: PRT-100
Display: 5-inch full-color high-resolution LCD screen
Pneumatic connection: 1/4 “stainless steel/PTFE (polytetrafluoroethylene)
Gas flow: 0.2L/min- 1L/min
Working temperature: -10ºC ~ +40ºC
Storage temperature: -10ºC ~ +50ºC
Environmental humidity: 90%RH, non-condensation
Power supply: 220VAC ±10%, 50/60Hz
Power: <50W
Dimension: 360*240*300mm
Weight: < 10kg
Accessories
Main tester 1 set
Sampling flow regulating valve pipe kit 1 set
Exhaust pipe 1pc
power cable 1pc
Connector 13pcs
Manual 1 copy
QC pass certificate 1 copy
Packing List 1 copy
Factory test report 1 copy
Product detail pictures:
Related Product Guide:
Our products are broadly identified and trustworthy by people and may meet continually modifying financial and social requires of China High Quality Meter Sf6 Leak Detection Supplier – GDP-713PM SF6 Gas Dew Point Tester (Chilled Mirror Method) – HV Hipot , The product will supply to all over the world, such as: Provence, America, Germany, We firmly think that we have the full capability to present you contented merchandise. Wish to collect concerns within you and build a new long-term synergy romantic relationship. We all significantly promise:Csame excellent, better selling price; exact selling price, better quality.
By Gill from Kyrgyzstan - 2017.05.02 18:28
The quality of the products is very good, especially in the details, can be seen that the company work actively to satisfy customer's interest, a nice supplier.
By tobin from Myanmar - 2018.11.11 19:52