China High Quality motor testing with a megger Factories – GDHX-9700 Phase Detector – HV Hipot

China High Quality motor testing with a megger Factories – GDHX-9700 Phase Detector – HV Hipot

Brief Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We're convinced that with joint endeavours, the business between us will bring us mutual benefits. We are able to guarantee you products high quality and competitive value for Tan Delta Test Of A Transformer, Tan Delta Test For Power Transformers, Tan Delta Test For Power Transformers, Trust us, you will find a better solution on car parts industry.
China High Quality motor testing with a megger Factories – GDHX-9700 Phase Detector – HV Hipot Detail:

General Information

GDHX-9700 Phase Detector is mainly used in electric power lines, phase, and phase sequence calibration in substation, with main functions including electrical inspection, phase calibration and phase sequence measurement. It uses double shielding and brand-new digital circuits, with strong anti-interference, accorded with EMC standards, suitable for various electromagnetic interference situations.

The high voltage phase signal of measured lead will be transmitted directly after treatment, the handset will receive and make phase comparison, determine the results after phase detection, real-time display phase angle difference and vector. It uses wireless transmission technology, safe and reliable, fast, and accurate, suitable for using at different voltage levels (10V-500KV). When checking the grid structure, it can accurately identify the relative phase of different leads for the three-phase connected line, without any electrical connection between two measurement components, which makes the application of the measurement device very flexible and safe.

Features

● Voltage range: 10V~500KV, applicable for various voltage grades.
● Accuracy: short distance: error ≤±3°; long distance: error ≤±3°.
● Sampling rate: 10 times/second.
● Date and time setting, date and time adjustment, easy for users to browse, view the historical data.
● Backlight setting: normally on, normally off, user-defined within 0~999s.
● Auto shut-down: never, user-defined within 0~999 minutes.
● In-phase: ≤20° (user-defined if phase threshold is within 0-90°, default 20°)
● Out-phase: >20° (user-defined if phase threshold is within 0-90°, default 20°)
● On-site calibration function: on-site calibration can be carried out on the tested wire to ensure the accuracy of phase angle.
● Multiple mode design, better applicability, more secure, more convenient.
● Unique human-machine interface, simple operation.
● FCC antenna design, stronger signal, easier to penetrate walls, doors, and barriers.
● Double shielding, strong anti-interference, in full compliance with EMC standards.
● Charts and data display, easier to read, with date and time display function.
● Qualitative measurement: display by acousto-optic signal.
● Quantitative measurement: real-time display of phase angle difference, error ≤5°.
● Phase sequence check: positive phase sequence, negative phase sequence (120°, 240°).
● Under GPS satellite timing service, the detection distance between detector Xa and Ya is ≥500km.
● Data storage capacity of 2000 groups. It can query and access to historical data.
● The length of standard insulation rod is 4m, and the applicable voltage grade of insulation rod is ≤ 220kV.

Technical Parameters

Voltage range

10V~500kV

Power supply

Hand-held unit: large capacity lithium battery

Xa & Ya detector: AA size alkaline battery (1.5V) 3pcs

Wireless transmission

Visual distance 150m

In-phase

≤20° (user-defined if phase threshold is within 0-90°)

Out-phase

>20° (user-defined if phase threshold is within 0-90°)

Display accuracy

Quantitative measurement ≤5°

Resolution of phase angle

1°

Phase sequence measurement

Phase sequence is determined through clockwise 120°/ counterclockwise 240°

Satellite timing range

2~30 minutes

Display

Positive type LCD screen, clear in the sunlight.

Working temperature

-35~+50℃

Storage temperature

-40~+55℃

Relative humidity

≤95%RH, condensing

Hand-held unit

0.31 kg

Detector Xa

0.16 kg

Detector Ya

0.16 kg


Product detail pictures:

China High Quality motor testing with a megger Factories –  GDHX-9700 Phase Detector – HV Hipot detail pictures

China High Quality motor testing with a megger Factories –  GDHX-9700 Phase Detector – HV Hipot detail pictures

China High Quality motor testing with a megger Factories –  GDHX-9700 Phase Detector – HV Hipot detail pictures


Related Product Guide:

All we do is often involved with our tenet " Purchaser to start with, Rely on initially, devoting over the food stuff packaging and environmental defense for China High Quality motor testing with a megger Factories – GDHX-9700 Phase Detector – HV Hipot , The product will supply to all over the world, such as: Bangladesh, Doha, Miami, As a way to make use of the resource on the expanding information and facts in international trade, we welcome prospects from everywhere on the web and offline. In spite in the top quality products we offer, effective and satisfying consultation service is supplied by our specialist after-sale service group. Solution lists and detailed parameters and any other info weil be sent to you timely for the inquiries. So please get in touch with us by sending us emails or contact us if you have any concerns about our firm. ou can also get our address info from our web site and come to our enterprise. or a field survey of our solutions. We're confident that we are going to share mutual results and build solid co-operation relations with our companions in this market. We're looking forward to your inquiries.
  • The goods we received and the sample sales staff display to us have the same quality, it is really a creditable manufacturer.
    5 Stars By Nora from Peru - 2017.02.18 15:54
    Good quality, reasonable prices, rich variety and perfect after-sales service, it's nice!
    5 Stars By Martina from Honduras - 2018.02.08 16:45

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us