China High Quality PD monitoring system Manufacturer – GDPD-306M Portable Ultrasonic Partial Discharge Detector – HV Hipot
China High Quality PD monitoring system Manufacturer – GDPD-306M Portable Ultrasonic Partial Discharge Detector – HV Hipot Detail:
GDPD-306M is widely used in the partial discharge detection of power systems. Including high voltage switchgear, ring mains, voltage/current transformer, transformer (include dry type transformer), GIS, overhead lines, cables, and other equipment insulation state detection.
The following indicators are used to measure the degree of discharge of electrical equipment:
Partial discharge intensity detection: By measuring the discharge signal in a power frequency cycle, the intensity of the partial discharge is characterized according to the maximum value (dB) in the discharge pulse sequence.
Partial discharge frequency detection: The device measures the discharge signal within a power frequency cycle, extracts the discharge pulses and characterizes the frequency of partial discharges according to the number of discharge pulses.
Features
● With different sensors to achieve partial discharge detection of almost all electrical equipment.
● Provide multiple discharge patterns such as time-domain waveform, PRPD, PRPS, etc., to realize the analysis of different discharge types.
● User-friendly man-machine interface facilitates the data management of different devices, including the traceability of historical data change trends, horizontal and vertical data analysis, and realizes a 360° comprehensive diagnosis of the tested device.
● Built-in ultrasonic sensor and transient earth voltage (hereinafter referred to as TEV) sensor, also can be connected to external special sensors for transformers, GIS, overhead lines, and cables.
● It adopts non-intrusive detection method, no need to power off during the test process, no need to configure additional high voltage source, it is more convenient to use than traditional pulsed partial discharge detector.
● The test bandwidth range is 30kHz ~ 2.0GHz, suitable for detection principles of various frequency bands.
Specifications
TEV Measurement | UHF Measurement | ||
Measurement range | 0-60dBmV | Detection frequency band | 300~1500MHz |
Resolution | 1dB | Measurement range | -75-0dBmV |
Accuracy | ±1dB | Accuracy | <1dBmV |
Max. pulse per cycle | 1400 | Sensor frequency band | 300-2000MHz |
Measurement frequency band | 1~100MHz | ||
AA measurement | AE measurement | ||
Measurement range | -6dBμV~68dBμV | Measurement range | -6dBμV~68dBμV |
Resolution | 1dB | Resolution | 1dB |
Accuracy | ±1dB | Accuracy | ±1dB |
Sensor center frequency | 40kHz | Frequency range | 40-200kHz |
HFCT measurement | |||
Sensor transmission impedance | 5mV/mA | ||
Detection frequency | 1~30MHz | ||
Sensitivity | ≤50pC | ||
Hardware | |||
Shell | ABS | ||
Display | 4.0inch RGB LCD screen | ||
Controller | ARM | ||
Connector | USB interface (charger port), Wireless WIFI 3.5mm stereo headphone jack, Wireless synchronization benchmark External ultrasonic sensor input |
||
Headphone | 8ohm minimum | ||
SD card | Standard 16G | ||
Built-in battery | 3.7V/1Ah lithium battery | ||
Working time | About 8 hours | ||
Charger | AC 90-264V or DC 5V | ||
Working temperatures | -20~+50℃ | ||
Humidity | 20~85% relative humidity | ||
Dimension, weight | 210*100*35(mm), 0.4kg (main unit) |
Packing List
Main unit |
1 |
Standard |
External Contact ultrasonic sensor |
1 |
For option, used for transformers, GIS, motors |
UHF sensor |
1 |
For option, used for GIS |
HFCT |
1 |
For option, used for power cable |
Test cable |
1 |
Standard |
Charger |
1 |
Standard |
USB cable |
1 |
For charging and PC communication |
User’s guide |
1 |
|
Factory test report |
1 |
Product detail pictures:
Related Product Guide:
Our well-equipped facilities and exceptional good quality manage throughout all stages of production enables us to guarantee total shopper satisfaction for China High Quality PD monitoring system Manufacturer – GDPD-306M Portable Ultrasonic Partial Discharge Detector – HV Hipot , The product will supply to all over the world, such as: Algeria, Mexico, Bhutan, Good quality and reasonable price have brought us stable customers and high reputation. Providing 'Quality Products, Excellent Service, Competitive Prices and Prompt Delivery', we are now looking forward to even greater cooperation with overseas customers based on mutual benefits. We'll work whole-heartedly to improve our solutions and services. We also promise to work jointly with business partners to elevate our cooperation to a higher level and share success together. Warmly welcome you to visit our factory sincerely.