China High Quality Sf6 Analyzer Measures Purity Factory – GDP-311IR SF6 Gas Purity Tester (IR Method) – HV Hipot
China High Quality Sf6 Analyzer Measures Purity Factory – GDP-311IR SF6 Gas Purity Tester (IR Method) – HV Hipot Detail:
General Information
GDP-311IR SF6 gas purity tester is a portable instrument for on site SF6 gas purity test developed by our company. The infrared principle SF6 gas purity testing sensor manufactured by European Sensor Company is used to test the purity of SF6 gas. With professional hardware chips and excellent software algorithms of STMicroelectronics, we have produced a new generation of SF6 gas purity analyzer.
Application
● Analysis purity of SF6 gas electrical equipment for electric power
● SF6 gas cylinder gas quality test
● Quality test of SF6 gas for recovery and reuse
● High purity gas manufacturing
● Semiconductor industry dry gas supply
● Research and development use
● Clean room/dry house monitoring
Features
● Imported high-precision sensors with self-calibration function, ensure the stability and reliability of purity detection data throughout the year.
● All gas path with high polymer material design, ensures no water wall hanging phenomenon and guarantees the test speed.
● The oil-free stainless-steel body regulating valve is used to ensure the accuracy of the measured value.
● Advanced software algorithms improve the test accuracy of sensors.
● Combined chassis configuration solution, users can easily combine related instruments and accessories. The overall package is carried, which makes the user have a more relaxed experience.
● Startup test, no need to oscillate.
● Temperature conversion and pressure data correction.
● Fuzzy computing technology.
● High-power lithium battery power, realize AC and DC dual power supply. No on-site AC power is required. Lithium battery power supply continues to work for more than 8 hours without the need of an external power supply.
● Anti-electromagnetic interference circuit design to ensure product reliability.
● Large-capacity memory, which can realize 1000 sets of data storage functions.
● Purity measurement accuracy is 0.5% in the full range. It can be applied to the measurement of high concentration SF6 gas and 70% content SF6 gas.
● The best test flow area shows that the user can adjust the gas flow intuitively and quickly. Reduce test time.
● The air inlet is designed with a miniature self-sealing joint, and the air path to be tested will not leak when the air path is disconnected.
● It can expand USB communication, serial communication, wireless communication module, and realize the communication and printing functions of the upper computer. (optional)
● The gas path pretreatment function can be used to purify the test pipeline before the field test work, which shortens the test time. (optional)
● The instrument has a test gas recovery function to recover the sulfur hexafluoride measurement gas. Protect the natural environment. (optional)
Specification
|
Measurement method |
Infrared Measurement Principle (NDIR series sensors) |
|
Working environment |
-20℃ ~ +60℃ |
|
Measuring range |
0 ~ 100% SF6 |
|
Response time |
[90%] 60s |
|
Accuracy |
± 0.5%FS |
|
Repeatability |
± 0.5% |
|
Resolution |
0.01% |
|
Display unit |
% |
|
Gas flow rate |
400 ~ 600ml/min |
|
Flow rate display |
0~1000mL import digital flowmeter |
|
Simple gas pressure |
≤1MPa |
|
Environment humidity |
90%RH |
|
Measurement value influence |
No effect of pressure and flow |
|
Power supply |
AC 220V±10%, 50Hz / DC Battery inside can work at least 8 hours |
|
Dimension |
395*295*155mm |
|
Weight |
about 2kg. |
Product detail pictures:
Related Product Guide:
Our well-equipped facilities and excellent quality control throughout all stages of production enables us to guarantee total customer satisfaction for China High Quality Sf6 Analyzer Measures Purity Factory – GDP-311IR SF6 Gas Purity Tester (IR Method) – HV Hipot , The product will supply to all over the world, such as: El Salvador, Albania, Chile, Our product quality is one of the major concerns and has been produced to meet the customer's standards. "Customer services and relationship" is another important area which we understand good communication and relationships with our customers is the most significant power to run it as a long term business.