China High Quality Shock Pulse Generator Suppliers – GDB-H Handheld Automatic Transformer Turns Ratio Tester – HV Hipot
China High Quality Shock Pulse Generator Suppliers – GDB-H Handheld Automatic Transformer Turns Ratio Tester – HV Hipot Detail:
General Information
GDB-H is a hand-held device. It can accurately measure turns ratio, group and phase angle, which is suitable for all kinds of transformers such as Z type transformers, rectifier transformers, electric furnace transformers, phase-shifting transformers, traction transformers, scott and invert-scott transformers.
Function Features
● 5.6inch TFT color LCD screen, intuitively display data and vector diagram.
● 3-phase testing at the same time. Single phase power input, with internal digital combination standard sine wave test source. It generates 3-phase test power (degree of distortion is less than 0.1%, degree of symmetry is better than 0.05%) by Hi-fi power amplifier. The test results have a better equivalence, and it won’t appear constituencies misjudgment.
● Both single phase measurement and 3-phase automatic test. It can measure polarity and phase angle under single phase or 3-phase test. One time complete the measurement of turns ratio, phase angle value, error, tap position, tap value of AB, BC, CA. Group number can be automatically identified.
● Phase angle measurement functions. Accurately measure the phase angle between high voltage and low voltage. It also can measure turns ratio and angle of “Non-integral point” transformers.
● Test results are displayed by figure and hexagonal vector, directly show the transformer connection group.
● No need to select connection way or connection group, it can measure Y/△, △/Y transformer without external short connection. It also can switch the connect ways according to the selected test items. Transformer without nameplate can be measured.
● Rapidly measure the turns ratio and ratio error of each tap changer position. Only input rated ratio one time, no need repeated input to calculate ratio error of each tap position.
● With functions of both turns ratio measurement and operation voltage ratio measurement. The operation ratio can truly reflect actual value of voltage ratio during operation.
● With good vibration resistance.
● The test source of this instrument is digital synthesis standard sine wave source. Distortion degree is less than 0.1%, not affected by power supply quality.
● Small size, light weight, easy to carry.
● Built-in high-capacity rechargeable Lithium-ion battery. Test can be completed without any power. One-time full charge takes more than 800times continuous measurement.
● Field calibration data can be saved, and the result can be transferred to PC by U disk.
Technical index
● TTR measurement range: 0.8~10000.
● Fast measurement speed: three-phase test can be completed within 60 seconds.
● Measurement accuracy:
Voltage measurement accuracy on HV side: 0.05%
Voltage measurement accuracy on LV side: 0.1%
Phase angle measurement accuracy: 0.1°
TTR measurement accuracy: 0.1% (0.8-3000)
0.2% (3000-10000)
● Weight: about 3Kg.
Accessories
GDB-H instrument | 1pc |
Accessory case | 1pc |
HV Test Lead with clamp | 1set |
LV Test Lead with clamp | 1set |
Fuse | 2pcs |
Charger | 1pc |
User’s guide | 1pc |
Factory test report | 1pc |
Product detail pictures:
Related Product Guide:
Our improvement depends on the superior equipment, excellent talents and continuously strengthened technology forces for China High Quality Shock Pulse Generator Suppliers – GDB-H Handheld Automatic Transformer Turns Ratio Tester – HV Hipot , The product will supply to all over the world, such as: Swaziland, El Salvador, Venezuela, We've got constructed strong and long co-operation relationship with an enormous quantity of companies within this business overseas. Immediate and specialist after-sale service supplied by our consultant group has happy our buyers. In depth Info and parameters from the merchandise will probably be sent to you for any thorough acknowledge. Free samples may be delivered and company check out to our corporation. n Portugal for negotiation is constantly welcome. Hope to get inquiries type you and construct a long-term co-operation partnership.