China High Quality Square Pulse Wave Generator Supplier – Impulse Voltage Test System – HV Hipot
China High Quality Square Pulse Wave Generator Supplier – Impulse Voltage Test System – HV Hipot Detail:
Features
● Complete equipment and wide voltage levels in the whole set of device.
● Small electric inductance in the return circuit of the impulse voltage generator, A band-stop filtering is adopted so that a standard impulse wave is still generated even under a large capacity load, and large load capacity.
● Large in voltage utilization coefficient.
● Convenient in wave adjustment, simple in operation, excellent in synchronization performance and reliable in motion.
● An automatic control technique is adopted in the constant-current charge, which is high automation and strong anti-interference capacity.
● A digital measurement and analysis system for the impulse test date are adopted, which increase the technical level and the efficiency of the impulse voltage tests.
Specifications
| Impulse voltage grade | 100kV-7200kV |
| Standard lightning wave | 1.2±30%/50±20%µS |
| Peak oscillation | <5% |
| Standard switching wave | 250±20%/2500±60%µS |
| Virtual front time of oscillating lightning wave | ≤15µS |
| Virtual front time of oscillating switching wave and virtual front time of oscillating switching impulse wave |
15µS-1mS |
| The minimum output voltage | ≥10%Un |
| Charging voltage instability | <±1% |
| Synchronizing range | ≥20% |
| Synchronous discharge error rate | <2% |
| Ignition range | 10%~100% |
| Working time | ≥70%UN Discontinuous work (charge-discharge 300s/time) <70%nn Continuous work (charge-discharge 120s/time) |
| Generator efficiency: lightning wave (no load) | ≥90% |
| Time to chopping | 2~5µS |
Product detail pictures:
Related Product Guide:
With our loaded encounter and considerate services, we have now been recognized as a trustworthy supplier for lots of worldwide consumers for China High Quality Square Pulse Wave Generator Supplier – Impulse Voltage Test System – HV Hipot , The product will supply to all over the world, such as: Zimbabwe, Israel, Libya, Till now, the goods list has been updated regularly and attracted clients from around the globe. Detailed facts is often obtained in our web-site and you'll be served with premium quality consultant service by our after-sale group. They are going to help you get comprehensive acknowledge about our products and make a satisfied negotiation. Company go to to our factory in Brazil is also welcome at any time. Hope to obtain your inquiries for any pleased co-operation.