China High Quality Surge Voltage Test Exporters – GDRB-B Transformer Frequency Response Analyzer – HV Hipot

China High Quality Surge Voltage Test Exporters – GDRB-B Transformer Frequency Response Analyzer – HV Hipot

Brief Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We have now probably the most innovative production equipment, experienced and qualified engineers and workers, regarded high quality control systems and also a friendly expert income team pre/after-sales support for Capacitors For Sale, Tan Delta Test Set Price, Uhf Pd Sensor, Striving hard to attain continual success determined by high quality, reliability, integrity, and complete understanding of current market dynamics.
China High Quality Surge Voltage Test Exporters – GDRB-B Transformer Frequency Response Analyzer – HV Hipot Detail:

General Information

Power transformer winding deformation tester (frequency response method) is based on the measurement of characteristic parameters of transformer internal windings, adopts the internal fault frequency response analysis (FRA) method, can accurately judge the internal faults of transformers.

After the completion of design and manufacture of transformers, the coils and internal structure are finalized, so for the coil of a multi-winding transformer, if the voltage level and winding method are the same, the corresponding parameters (Ci, Li) of each coil shall be determined. Therefore, the frequency characteristics response of each coil also will be determined, so the frequency spectrums of the corresponding coils of three phases are comparable.

During the test of transformer, in case of inter-turn, inter-phase short circuit, or relative coil displacement caused by collisions during transport, as well as coil deformation resulted from electromagnetic tension during operation under short circuit and fault conditions, the distribution parameters of transformer windings will change, which thereby in turn affects and changes the transformers’ original frequency domain characteristics, namely the frequency response change in magnitude and the resonant frequency points shift. The transformer winding tester developed according to the response analysis method is the novel NDT equipment for detecting transformer internal fault. It applies to the detection of internal structure fault in 63kV-500kV power transformers.

Transformer winding deformation tester is to determine the degree of changes in internal windings of the transformer based on the quantity of change, magnitude and region affecting change and tendency of frequency response change which are quantized from the response changes in different frequency domains of transformer’s internal winding parameters, and then it can help to determine whether the transformer has been severely damaged, or need a major overhaul in accordance with the measurement results.

For the transformer in operation, no matter whether the frequency domain characteristic drawing is saved, by comparing the differences between the inter-coil characteristic spectra of faulted transformer, it can determine the extent of the failure as well. Of course, if you have saved the original transformer windings feature drawings, it will be simpler to provide a precise basis for operating conditions, post-fault analysis and maintenance overhaul of the transformer.

Transformer winding deformation tester is constituted by a laptop computer and micro controller forming a precision measurement system with the compact structure, easy operation, with more complete test analysis function, which can be operated referring to the instruction manual or through short-term training.

Features

● Acquisition and control using high-speed, highly integrated microprocessor.
● Communication USB interface used between the laptop and instrument.
● Wireless WIFI interface or Bluetooth (optional) used between the laptop computer and instrument.
● Hardware adopts dedicated DDS digital high-speed scanning technology (USA), which can accurately diagnose the faults like winding distorted, bulged, shift, tilt, inter-turn short-circuits deformation and inter-phase contact short-circuit.
● High-speed dual-channel 16-bit A/D sampling (in field test, move tap changer, and the wave curve shows obvious changes).
● Signal output amplitude is adjusted by software, and the peak value of amplitude is ± 10V.
● The computer will automatically analyze the test results and generate electronic documents (Word).
● The instrument has dual measurement features: linear frequency scanning measurement and segment frequency scanning measurement, compatible with measurement mode of two technical groups in China
● The amplitude-frequency characteristics are in line with the national technical specifications on amplitude-frequency characteristics tester. X-coordinate (frequency) has linear indexing and logarithmic indexing, so the user can print out the curve with linear indexing and logarithmic indexing. The user can choose either according to actual needs.
● Automatic test data analysis system,
Horizontal comparison of winding similarity between three phases A, B and C
The results are as follows:
● Excellent consistency
● Good consistency
● Poor consistency
● Worse consistency
Longitudinal comparison A-A, B-B, C-C calls the original data and the current data in the same phase for winding deformation comparison
The analysis results are:
● Normal winding
● Mild deformation
● Moderate deformation
● Severe deformation
Word electronic document can be automatically generated for saving and printing.
The instrument can fully meet the technical requirements of electricity standard DL/T911-2004 “Frequency response analysis on winding deformation of power transformers”.

Specifications

Scan mode:
1. Linear scanning distribution
Scanning measurement range: (10Hz) -(10MHz) 40000 scanning point, resolution 0.25kHz, 0.5kHz and 1kHz.
2. Segment frequency scanning measurement distribution
Frequency scanning measurement range: (0.5kHz) – (1MHz), 2000 scanning points; (0.5kHz) – (10kHz); (10kHz) – (100kHz); (100kHz) – (500kHz); (500kHz) – (1000kHz)

Other technical parameters:
1. Amplitude measurement range: (-120dB) to (+20 dB);
2. Amplitude measurement accuracy: 0.1dB;
3. Scanning frequency accuracy: 0.005%;
4. Signal input impedance: 1MΩ;
5. Signal output impedance: 50Ω;
6. Signal output amplitude: ± 20V;
7. In-phase test repetition rate: 99.9%;
8. Measuring instruments dimensions (LxWxH): 350X300X140 (mm);
9. Instrument’s aluminum box dimension (LxWxH): 390X310X340 (mm);
10. Overall weight: 13kg;
11. working temperature: -10℃~+40℃;
Storage temperature: -20℃~+70℃;
Relative humidity: <90%, Non-condensing;

Accessories

Main unit

1

Frequency response test lead 50W/(>15m)

2

Test clamp, yellow, green(200A)

2

Ground cable (black, 5M copper wire)

4

Grounding clamp(black)

2

USB communication cable

1

Installation Software CD-ROM VCD Format

1

Installation Software USB disk 16G

1

Fuse 0.5A

3

Power cord & adapter

1

User’s guide

1

Warranty card

1

Packing list

1

Factory test report

1


Product detail pictures:

China High Quality Surge Voltage Test Exporters –  GDRB-B Transformer Frequency Response Analyzer – HV Hipot detail pictures

China High Quality Surge Voltage Test Exporters –  GDRB-B Transformer Frequency Response Analyzer – HV Hipot detail pictures


Related Product Guide:

Our firm has been concentrating on brand strategy. Customers' satisfaction is our best advertising. We also offer OEM provider for China High Quality Surge Voltage Test Exporters – GDRB-B Transformer Frequency Response Analyzer – HV Hipot , The product will supply to all over the world, such as: Liberia, El Salvador, Gambia, We hope we can establish long-term cooperation with all of the customers, and hope we can improve competitiveness and achieve the win-win situation together with the customers. We sincerely welcome the customers from all over the world to contact us for anything you need!Welcome all customers both at home and abroad to visit our factory. We hope to have win-win business relationships with you, and create a better tomorrow.
  • The factory workers have rich industry knowledge and operational experience, we learned a lot in working with them,we are extremely grateful that we can encount a good company has excellent wokers.
    5 Stars By Esther from Georgia - 2018.12.14 15:26
    This company can be well to meet our needs on product quantity and delivery time, so we always choose them when we have procurement requirements.
    5 Stars By Iris from San Diego - 2018.11.28 16:25

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us