To be a result of ours specialty and repair consciousness, our corporation has won a good popularity amid consumers everywhere in the environment for Discharge Capacitor With Multimeter, Sine Waves Generator, Winding Resistance Test Of Motor, We welcome clients, enterprise associations and friends from all components from the earth to make contact with us and find cooperation for mutual positive aspects.
China High Quality Tan Delta Kit Factories – AC DC High Voltage Divider – HV Hipot Detail:

GDFR-C1 series AC/DC Voltage Meter

GDFR-C1 series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. It consists of voltage divider and measurement instrument.

Features

● Balance type equal potential shield structure.
● Fully-sealed insulation cylinder with internal excellent components.
● High accuracy and linearity, good stability and anti-interference ability.
● The voltage ratio can be customized, suitable for calibration.
● Upside down is forbidden when installation.

Technical Specifications

Model No. GDFR-C1-50 GDFR-C1-100 GDFR-C1-150 GDFR-C1-200 GDFR-C1-300 GDFR-C1-400
Voltage(kV) 50 100 150 200 300 400
DC frequency (Hz) <2
AC frequency (Hz) 30-300
Accuracy AC: 1.5%/DC: 1.0%
Accuracy for option (G type) AC: 1.0%/DC: 0.5% –
Accuracy for option (H type) AC: 0.5%/DC: 0.5% – –
Impedance
(MΩ)
650 1280 2000 2640 4000 5360
Capacitance
(pF)
320 250 400 / 160 300 200 300
Voltage ratio 1000:1 or 10000:1(or customized)
Dimension
(mm)
150×150 160×160 350×350 800×800 1000×1000
Cable impedance(Ω) 50 / 75
Range 1. Low range: 0-20kV
2. High range: 20kV-rated voltage
3. Low range: 0-200kV
4. High range:200kV-rated voltage
Cable length(m) 3 4 6 6 10 10
Weight(kg) 5.5 9.5 12.5 14.5 27 40
Packing Medium Polyurethane foaming agent
Operation temperature 0℃-45℃
Relative humidity <85%RH, no condensation
Altitude <1500m (or customized)
Use condition Indoor use or outdoor use in Sunny day

 


Product detail pictures:

China High Quality Tan Delta Kit Factories –  AC DC High Voltage Divider – HV Hipot detail pictures

China High Quality Tan Delta Kit Factories –  AC DC High Voltage Divider – HV Hipot detail pictures

China High Quality Tan Delta Kit Factories –  AC DC High Voltage Divider – HV Hipot detail pictures


Related Product Guide:

We retain improving upon and perfecting our items and repair. At the same time, we perform actively to do research and progress for China High Quality Tan Delta Kit Factories – AC DC High Voltage Divider – HV Hipot , The product will supply to all over the world, such as: Brasilia, UK, Amsterdam, In the new century, we promote our enterprise spirit "United, diligent, high efficiency, innovation", and stick to our policy"basing on quality, be enterprising, striking for first class brand". We would take this golden opportunity to create bright future.
  • As an international trading company, we have numerous partners, but about your company, I just want to say, you are really good, wide range, good quality, reasonable prices, warm and thoughtful service, advanced technology and equipment and workers have professional training, feedback and product update is timely, in short, this is a very pleasant cooperation, and we look forward to the next cooperation!
    5 Stars By Monica from Argentina - 2017.06.22 12:49
    This company has the idea of "better quality, lower processing costs, prices are more reasonable", so they have competitive product quality and price, that's the main reason we chose to cooperate.
    5 Stars By Edith from Namibia - 2017.12.31 14:53

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us