China High Quality tension testing equipment Suppliers – GDND-800 Freezing Point Tester – HV Hipot
China High Quality tension testing equipment Suppliers – GDND-800 Freezing Point Tester – HV Hipot Detail:
General Information
1. Transformer oil freezing point tester has the characteristics of exquisite structural design and unique manufacturing process. It conforms to GB/T 3535 and GB/T510 standards and is used to determine the pour point of petroleum products.
2. This instrument adopts compressor refrigeration technology to save energy, simple operation and long service life. Its main technical indicators such as cooling rate and cooling capacity have surpassed similar foreign products.
Working conditions
1. The instrument should be placed on a flat and stable workbench, and air convection should be minimized in the environment.
2. This product may involve flammable materials when used. It is not allowed to have an open flame (or a device that produces spark) close to it during operation.
3. When the instrument is not in use, it should be placed in a dry and ventilated place.
4. The power supply is single-phase three-wire system and must have a good grounding terminal.
5. The environmental conditions for the instrument use are: ambient temperature 5~30℃, humidity ≤85%, working power supply AC220V±10%, 50Hz.
Specification
| Refrigerant | R13 R502 |
| Cooling time | ≤100min (ambient temperature ≤30℃) |
| Stop interval | >30min |
| Stirring motor power | 22W * 2 |
| Stirring motor allows temperature rise | 80℃ |
| Power | 800W |
| Voltage | 220V±10%, 50Hz±1Hz |
| Temperature control range | room temperature ~ -70℃ |
| Temperature control accuracy | ±0.5℃ |
| Temperature display | LED |
| Temperature sensor | Pt100 |
| Timer | LED |
Product detail pictures:
Related Product Guide:
abide by the contract", conforms on the market requirement, joins from the market competition by its good quality likewise as provides more comprehensive and superb support for customers to let them become large winner. The pursue of the company, is definitely the clients' pleasure for China High Quality tension testing equipment Suppliers – GDND-800 Freezing Point Tester – HV Hipot , The product will supply to all over the world, such as: Johannesburg, Nigeria, Ireland, We have more than 100 works in the plant, and we also have a 15 guys work team to service our customers for before and after sales. Good quality is the key factor for the company to stand out from other competitors. Seeing is Believing, want more information? Just trial on its products!