China High Quality Testing A Capacitor With A Voltmeter Factory – PD free Variable Frequency Test System – HV Hipot
China High Quality Testing A Capacitor With A Voltmeter Factory – PD free Variable Frequency Test System – HV Hipot Detail:
GDYT-350kVA/70kV PD free Resonant Test System is composed of PD free variable frequency power supply, HV measuring box, excitation transformer, isolation transformer, Resonant reactor, and capacitive voltage divider.
This test system does not have the problem of excessive starting current. Using a smaller capacity power supply can complete a test equivalent to 30 to 60 times of the power supply, which greatly alleviates the problem of insufficient capacity of the field test power supply.
Features
● Safety and reliable. It has many functions, including discharge and breakdown protection, over-voltage and over-current setting protection, test power off protection, zero protection, over-heat protection etc. When any protection happened, the system will immediately cut off output and power, to ensure the safety of operators, test system and test object.
● Simple operation and easy wiring.
● 320*240 LCD display, display output voltage, output current, frequency, environmental temperature, output waveform, date, timing etc.
● Automatic searching resonant frequency, automatic frequency setting.
● Test voltage and time can be set.
● Output sine wave distortion rate of HV circuit is lower than 1%, which is no damage to test object.
● Use indoor or outdoor. With hooks, suitable for hoisting on-site.
General Use Condition
● Altitude: ≤ 3000m.
● Environment temperature: -10℃ to 40℃.
● Storage temperature: -20℃ to 50℃
● Sunlight Strength: 0.1W/cm2 (wind speed 0.5m/s)
● Max. Daily temperature difference: 25℃.
● Using in no conductive dust, no-fire and no-explosion, corrosive free place.
● Use in outdoor or indoor. Indoor storage.
● Reliable grounding terminal should be available, earth resistance <0.5Ω
● The installation gradient of reactor should be no more than 5°.
Product detail pictures:
Related Product Guide:
In an effort to finest meet up with client's requirements, all of our operations are strictly performed in line with our motto "High High quality, Competitive Rate, Fast Service" for China High Quality Testing A Capacitor With A Voltmeter Factory – PD free Variable Frequency Test System – HV Hipot , The product will supply to all over the world, such as: Lithuania, Mexico, America, Our advanced equipment, excellent quality management, research and development ability make our price down. The price we offering may not be the lowest, but we guarantee it is absolutely competitive! Welcome to contact us immediately for future business relationship and mutual success!