GDFR-D1 series AC/DC Voltage Meter
GDFR-D1 series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. The digital meter and divider are equipped in one unit.
Features
● Balance type equal potential shield structure.
● Fully-sealed insulation cylinder with internal excellent components.
● High accuracy and linearity, good stability and anti-interference ability.
● With good filling materials, which make the structure smaller and weight lighter, and minimize internal partial discharge.
● Small size, light weight, easy to carry in the field work.
● Inner shield anti-interference system.
● The voltage ratio can be customized, suitable for calibration.
● External voltage meter can be connected.
Technical Specifications
| Model No. | GDFR-D1-50 | GDFR-D1-100 | GDFR-D1-150 | GDFR-D1-200 | GDFR-D1-300 | GDFR-D1-400 | |
| Voltage(kV) | 50 | 100 | 150 | 200 | 300 | 400 | |
| DC frequency(Hz) | <2 | ||||||
| AC frequency(Hz) | 30-300 | ||||||
| Accuracy (G type) |
AC: 1.0%/DC: 0.5% | – | |||||
| Accuracy (H type) |
AC: 0.5%/DC: 0.5% | – | – | ||||
| Impedance (MΩ) |
650 | 1280 | 2000 | 2640 | 4000 | 5360 | |
| Capacitance (pF) |
500 | 250 | 400/160 | 300 | 200 | 300 | |
| Voltage ratio | 1000:1 or 10000:1(or customized) | ||||||
| Height (mm) | 500 | 650 | 900 | 1200 | 1750 | 2350 | |
| Dimension (mm) |
150×150 | 160×160 | 200×200 | 260×260 | 800×800 | ||
| Cable impedance(Ω) | 50 / 75 | ||||||
| Range | 1. Low range: 0-20kV 2. High range: 20kV-rated voltage |
1. Low range: 0-200kV 2. High range: 200kV-rated voltage |
|||||
| Cable length(m) | 3 | 4 | 5 | 6 | 8 | 10 | |
| Weight(kg) | 5.5 | 6.9 | 10.6 | 14.1 | 23.5 | 48.2 | |
| Packing Medium | Imported dry type high polymer materials | ||||||
| Operation temperature | 0℃-45℃ | ||||||
| Relative humidity | <85%RH, no condensation | ||||||
| Altitude | <1500m(or customized) | ||||||
| Use condition | Indoor use or outdoor use in Sunny day | ||||||
Product detail pictures:
Related Product Guide:
We insist on the principle of development of 'High quality, Efficiency, Sincerity and Down-to-earth working approach' to provide you with excellent service of processing for China High Quality Testing Ac Capacitor Factory – High voltage divider GDFR-D1 – HV Hipot , The product will supply to all over the world, such as: Liberia, Morocco, USA, "Make the women more attractive "is our sales philosophy. "Being customers' trusted and preferred brand supplier" is the goal of our company. We've been strict with every part of our work. We sincerely welcome friends to negotiate business and start cooperation. We hope to join hands with friends in different industries to create a brilliant future.