China High Quality Testing Capacitors In Circuit Factories – Partial Discharge Test System GDYT series – HV Hipot Detail:
GDYT is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power supply for testing object such as transformer, mutual inductor and lightning arresters. It widely used in electrical manufacturing, power operation departments, research institutes and universities.
It includes below components
1. Hipot Test Control Unit GDYD
2. PD-free Gas type transformer YDQW
3. Coupling capacitor
4. Protective resistor
5. Isolation filter LBQ
6. Partial discharge detector
Features
● Advanced PD-free epoxy insulating tube, small partial discharge capacity.
● Low impedance voltage, better than national standard.
● Automatic control technology, good anti-interference performance.
● Rapid electronic protection, high reliability.
Specifications
● Rated Capacity (KVA) : 5~5500
● High Voltage (KV): 50~250
● Low Voltage (KV): 0.22/0.38~0.38/0.6~0.6/3~3/6/10
● Top cover(mm): accordance with specific conditions
| Model | Rated Capacity | High Voltage | Low Voltage | Top cover OD x Height | Weight |
| (KVA) | (KV) | (KV) | (mm) | (KG) | |
| GDYT-5/50 | 5 | 50 | 0.22/0.38 | 320×450 | 42 |
| GDYT-50/50 | 50 | 50 | 0.22/0.38 | 850×945 | 360 |
| GDYT-10/100 | 10 | 100 | 0.22/0.38 | 570×725 | 150 |
| GDYT-50/100 | 50 | 100 | 0.22/0.38 | 850×1000 | 400 |
| GDYT-100/100 | 100 | 100 | 0.22/0.38 | 850×1000 | 800 |
| GDYT-15/150 | 15 | 150 | 0.22/0.38 | 1165×1400 | 500 |
| GDYT-75/150 | 75 | 150 | 0.22/0.38 | 1350×1570 | 1100 |
| GDYT-150/150 | 150 | 150 | 0.38/0.6 | 1350×1570 | 1400 |
| GDYT-20/200 | 20 | 200 | 0.22/0.38 | 1165×1850 | 760 |
| GDYT-100/200 | 100 | 200 | 0.22/0.38 | 1450×1950 | 1800 |
| GDYT-200/200 | 200 | 200 | 0.38/0.6 | 1800×1950 | 3100 |
| GDYT-25/250 | 25 | 250 | 0.22/0.38 | 1250×2200 | 1250 |
| GDYT-150/250 | 150 | 250 | 0.38/0.6 | 1450×2200 | 1900 |
| GDYT-250/250 | 250 | 250 | 0.38/0.6 | 2000×2300 | 3100 |
| GDYT-500/250 | 500 | 250 | 3/6 | 200×2600 | 5800 |
| GDYT-1000/250 | 1000 | 250 | 3/6 | 2200×2600 | 8200 |
Product detail pictures:
Related Product Guide:
We follow our enterprise spirit of "Quality, Efficiency, Innovation and Integrity". We aim to create much more worth for our buyers with our abundant resources, highly developed machinery, experienced workers and great providers for China High Quality Testing Capacitors In Circuit Factories – Partial Discharge Test System GDYT series – HV Hipot , The product will supply to all over the world, such as: Paraguay, New Delhi, Chile, We have established long-term, stable and good business relationships with many manufacturers and wholesalers around the world. Currently, we are looking forward to even greater cooperation with overseas customers based on mutual benefits. Please feel free to contact us for more details.