China High Quality Testing In Breaker Supplier – GDSL-D Seriese Digital Primary Current Injection Test Set – HV Hipot
China High Quality Testing In Breaker Supplier – GDSL-D Seriese Digital Primary Current Injection Test Set – HV Hipot Detail:
Adoption of Standard
● DL/T 596-2005 “Procedure Test Procedures for Electrical Equipment”
● GB1094.1-GB1094.6-96 “Shell protection level”
● GB2900 “Electrical Terminology”
● GB/T16927.1~2-1997 “High Voltage Test Technology”
● GB4793-1984 “Safety Requirements for Electronic Measuring Instruments”
● GB191 “Package Storage and Transportation Mark”
● GB/T.311-1997 “Insulation and coordination of high voltage power transmission and transformation equipment”
Features
● Using high conductivity copper as the output electrode, the contact surface is large and the flow capacity is strong.
● Brushed aluminum plate with a new process, simple and eye-catching, wear-resistant and pollution-resistant.
● The all-metal spray plastic case and the internationally popular camel gray tone are solid and reliable, ensuring the reliability of logistics.
● The use of brake universal casters makes movement and fixing more flexible and convenient.
● Wedge-shaped airflow duct to improve heat dissipation and greatly extend service life.
● The whole machine is small in size and light in weight, which is very suitable for field use.
Functions
● It has zero protection function to prevent the impact of large current from causing damage to the sample. It cannot be started when it is not at zero position.
● Impact selection function, when the circuit breaker quick-break test is performed, the zero protection function can be cut off and the required current value can be directly output.
● Output current mode: The true RMS value is continuously adjustable.
● The output current is a standard sine wave, and the waveform distortion rate is less than 5%.
● Voltage and current display adopts new high-precision LED digital display
● Switchable size current range to improve display fineness for more accurate readings.
● The power supply voltage and regulator output voltage can be switched to display for easy viewing.
● The equipment capacity is designed for short-term, intermittent work in 5 minutes.
● For batch testing, close for 10 minutes after 2.5 minutes of continuous operation.
● It can measure the current action time of the tested component and record the lock action time synchronously. (optional)
● Measured time range: 0.001S~999.999S Resolution 1ms, measurement error: 0.005% range ± 2digs. (optional)
● The test value of primary current and secondary current can be directly displayed to facilitate the transformer ratio test. (optional)
● Secondary current range 0~5A resolution 1mA (optional)
● If the temperature rise (30 minutes – 24 hours) should be customized according to the long-term work temperature rise. (optional)
● Can be customized three-phase with balance adjustment riser (optional)
● Can be customized AC and DC riser (optional)
Specifications
Model | Output capacity (kVA) | Output current (A) | Power Supply (V) | Open circuit voltage (V) | Power phase | Mark | |
GDSL-D-500 | 3 | 500 | 220 | 6 | LN | Integrated | |
GDSL-D-1000 | 6 | 1000 | 220 | 6 | LN | Integrated | |
GDSL-D-1500 | 9 | 1500 | 220 | 6 | LN | Integrated | |
GDSL-D-2000 | 12 | 2000 | 220 or 380 | 6 | LN | AB | Integrated or combination |
GDSL-D-2500 | 15 | 2500 | 220 or 380 | 6 | LN | AB | Integrated or combination |
GDSL-D-3000 | 18 | 3000 | 220 or 380 | 6 | AB | Integrated or combination | |
GDSL-D-4000 | 24 | 4000 | 380 | 6 | AB | combination | |
GDSL-D-5000 | 30 | 5000 | 380 | 6 | AB | combination | |
GDSL-D-6000 | 36 | 6000 | 380 | 6 | AB | combination | |
GDSL-D-8000 | 48 | 8000 | 380 | 6 | AB | combination | |
GDSL-D-10000 | 60 | 10000 | 380 | 6 | AB | combination | |
GDSL-D-12000 | 72 | 12000 | 380 | 6 | AB | combination | |
GDSL-D-15000 | 90 | 15000 | 380 | 6 | AB | combination | |
Can be customized due to customer;s special requirements |
Accessories
Primary current injection test set | 1 piece |
Power cord | 1 piece |
Grounding Wire | 1 piece |
High Current line(standard 2m) | 2 piece |
Certificate | 1 copy |
Manual | 1 copy |
Packing list | 1 copy |
Test Report | 1 copy |
Product detail pictures:
Related Product Guide:
The incredibly abundant projects administration experiences and 1 to one provider model make the superior importance of small business communication and our easy understanding of your expectations for China High Quality Testing In Breaker Supplier – GDSL-D Seriese Digital Primary Current Injection Test Set – HV Hipot , The product will supply to all over the world, such as: Grenada, South Korea, Thailand, Most problems between suppliers and clients are due to poor communication. Culturally, suppliers can be reluctant to question items they do not understand. We break down people barriers to ensure you get what you want to the level you expect, when you want it. Faster delivery time and the product you want is our Criterion .
By Priscilla from UAE - 2018.05.22 12:13
It is not easy to find such a professional and responsible provider in today's time. Hope that we can maintain long-term cooperation.
By Hulda from Plymouth - 2017.12.02 14:11