China High Quality testing of instrument transformer Manufacturers – GDJF-2006 Partial Discharge Analyzer – HV Hipot
China High Quality testing of instrument transformer Manufacturers – GDJF-2006 Partial Discharge Analyzer – HV Hipot Detail:
Features
● With high speed, big capacity data acquisition card. Continuously collect partial discharge data, good repeatability, and high accuracy.
● Functions of testing, analyzing (multi-parameter analysis, two-dimension atlas analysis, three-dimension atlas analysis), data storage, report, and print. Display waveform (ellipse, sine wave, line), discharge value and test voltage.
● Suitable for 50Hz, 150Hz frequency power supply, up to 400Hz. Automatic tracking external power supply frequency.
● Big color LCD screen. Large memory, with USB port.
● With anti-false operation function. Automatic adjusting gain during testing and rectifying.
● Anti-interference design.
Specifications
● Capacitance range: 6pF-250μF
● Sensitivity: <0.02pc (capacitance at 50pF)
● Amplifier: 3db low frequency fl 10kHz, 20kHz, 30kHz, 50kHz, 80kHz. / 3db high frequency fh 100kHz, 200kHz, 300kHz, 400kHz, 500kHz.
● Gain adjustment range>120db, gain difference 20±1db, asymmetry of positive/negative pulse response<1db
● Time window: width 1°-360°, can be rotated at any time.
● Test voltage: 0-200kV, error <3% F.S.
● Acquisition channel: 4 or 6channels/card.
● Input impedance: 1MΩ.
● Max. Sampling rate: 20Mhz.
● AD resolution: 12bit, DC accuracy 0.2%.
● Sampling length of each channel: 8M.
● Triggering mode: Manual, internal triggering, external triggering.
● Bandwidth of acquisition card: 3Mhz(-3db).
● Weight: about 15kg.
Product detail pictures:
Related Product Guide:
Well-run devices, expert profits group, and better after-sales companies; We have been also a unified huge family, everybody keep on with the organization worth "unification, determination, tolerance" for China High Quality testing of instrument transformer Manufacturers – GDJF-2006 Partial Discharge Analyzer – HV Hipot , The product will supply to all over the world, such as: Bangladesh, Mecca, Ghana, We hope to have long-term cooperation relationships with our clients. If you are interested in any of our products, make sure you do not hesitate to send enquiry to us/company name. We ensure that you can be totally satisfied with our best solutions!