China High Quality testing of transformer Factory – GDJF-2007 Digital Partial Discharge Analyzer – HV Hipot
China High Quality testing of transformer Factory – GDJF-2007 Digital Partial Discharge Analyzer – HV Hipot Detail:
Picture only for reference first.
GDJF-2007 Digital Partial Discharge Analyzer is widely used for detecting partial discharge of high voltage equipment such as power transformers, instrument transformer, HV circuit breaker, GIS, Zinc oxide surge arrester, power cable. It also can make type tests and monitor insulation operation.
It includes main unit, PD software, current transformer, input unit, calibration pulse generator, input adapter, antenna amplifier and connection cable etc.
Features
● 12inch LCD display, with portable design, rugged and durable, easy to use.
● Strong anti-interference ability, accurate. Using digital filtering technology, field interference can be effectively eliminated, and partial discharge measurement can be realized in a strong interference environment.
● Multi-channel data acquisition. One screen can display 2channels or 4channels waveform.
● Powerful software function. With PD measurement, analysis, PD repeated discharge times N measurement, analysis and anti-fixed interference, anti-dynamic interference. Free choice of ellipse, straight line and sinusoidal display mode. Measure and Observe discharge pulse by window, and test voltage and current, partial discharge can be measured at the same time. All test data of 2channels can be saved timely. Test waveform can be saved, re-displayed and analyzed. The gain range of each channel can be coarse adjusted and fine adjusted. Digital window-opening technology, to avoid the influence of interference on measurement. Phase window opening, single window and double window can be selected. Window can be opened freely within 360degree.
● Accorded with IEC60270 standard.
Specifications
● Capacitance range: 6pF-250μF
● Sensitivity: 0.1pc
● Measurement channel: 2 or 4pcs independent channels
● Sampling accuracy: 12Bit
● Sampling rate: Max. 100MHz per channel
● Measurement range: 0.1pc-10000nc.
● Dynamic range: >80db.
● Measurement frequency band: 10kHz-1MHz at 3db.
● Frequency range of test power: 50-400Hz.
● Programmable filter
Low frequency: 10K, 20K, 40K, 80K;
High frequency: 100K, 200K, 300K, 1000K.
● Environmental temperature: -15℃–50℃
● Relative humidity: ≤95% (20℃)
● Altitude: ≤3000m.
● Impact ability: 5000V at each input port and power terminal (positive, negative and AC)
● Power input: AC220V±10%, 45-65Hz, power <500W.
● Weight: about 15kg.
● Dimension: 58*36*32CM
Product detail pictures:
Related Product Guide:
Our products are greatly recognized and trustworthy by users and will fulfill continually shifting economic and social requires for China High Quality testing of transformer Factory – GDJF-2007 Digital Partial Discharge Analyzer – HV Hipot , The product will supply to all over the world, such as: Florida, Greek, Bulgaria, Our company has always insisted on the business principle of "Quality, Honest, and Customer First" by which we have won the trust of clients both from at home and abroad. If you are interested in our products, please do not hesitate to contact us for further information.
This is the first business after our company establish, products and services are very satisfying, we have a good start, we hope to cooperate continuous in the future!





