China High Quality The Capacitors Manufacturers – Partial Discharge Test System GDYT series – HV Hipot
China High Quality The Capacitors Manufacturers – Partial Discharge Test System GDYT series – HV Hipot Detail:
GDYT is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power supply for testing object such as transformer, mutual inductor and lightning arresters. It widely used in electrical manufacturing, power operation departments, research institutes and universities.
It includes below components
1. Hipot Test Control Unit GDYD
2. PD-free Gas type transformer YDQW
3. Coupling capacitor
4. Protective resistor
5. Isolation filter LBQ
6. Partial discharge detector
Features
● Advanced PD-free epoxy insulating tube, small partial discharge capacity.
● Low impedance voltage, better than national standard.
● Automatic control technology, good anti-interference performance.
● Rapid electronic protection, high reliability.
Specifications
● Rated Capacity (KVA) : 5~5500
● High Voltage (KV): 50~250
● Low Voltage (KV): 0.22/0.38~0.38/0.6~0.6/3~3/6/10
● Top cover(mm): accordance with specific conditions
| Model | Rated Capacity | High Voltage | Low Voltage | Top cover OD x Height | Weight |
| (KVA) | (KV) | (KV) | (mm) | (KG) | |
| GDYT-5/50 | 5 | 50 | 0.22/0.38 | 320×450 | 42 |
| GDYT-50/50 | 50 | 50 | 0.22/0.38 | 850×945 | 360 |
| GDYT-10/100 | 10 | 100 | 0.22/0.38 | 570×725 | 150 |
| GDYT-50/100 | 50 | 100 | 0.22/0.38 | 850×1000 | 400 |
| GDYT-100/100 | 100 | 100 | 0.22/0.38 | 850×1000 | 800 |
| GDYT-15/150 | 15 | 150 | 0.22/0.38 | 1165×1400 | 500 |
| GDYT-75/150 | 75 | 150 | 0.22/0.38 | 1350×1570 | 1100 |
| GDYT-150/150 | 150 | 150 | 0.38/0.6 | 1350×1570 | 1400 |
| GDYT-20/200 | 20 | 200 | 0.22/0.38 | 1165×1850 | 760 |
| GDYT-100/200 | 100 | 200 | 0.22/0.38 | 1450×1950 | 1800 |
| GDYT-200/200 | 200 | 200 | 0.38/0.6 | 1800×1950 | 3100 |
| GDYT-25/250 | 25 | 250 | 0.22/0.38 | 1250×2200 | 1250 |
| GDYT-150/250 | 150 | 250 | 0.38/0.6 | 1450×2200 | 1900 |
| GDYT-250/250 | 250 | 250 | 0.38/0.6 | 2000×2300 | 3100 |
| GDYT-500/250 | 500 | 250 | 3/6 | 200×2600 | 5800 |
| GDYT-1000/250 | 1000 | 250 | 3/6 | 2200×2600 | 8200 |
Product detail pictures:
Related Product Guide:
It really is a good way to further improve our goods and service. Our mission would be to acquire inventive items to buyers with a very good encounter for China High Quality The Capacitors Manufacturers – Partial Discharge Test System GDYT series – HV Hipot , The product will supply to all over the world, such as: New York, New Orleans, Mauritania, Upon today, we have customers from all over the world, including USA, Russia, Spain, Italy, Singapore, Malaysia, Thailand, Poland, Iran and Iraq. The mission of our company is to provide the highest quality products with best price. We are looking forward to doing business with you!