China High Quality Transformer Capacitance Suppliers – High voltage divider GDFR-D1 – HV Hipot
China High Quality Transformer Capacitance Suppliers – High voltage divider GDFR-D1 – HV Hipot Detail:
GDFR-D1 series AC/DC Voltage Meter
GDFR-D1 series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. The digital meter and divider are equipped in one unit.
Features
● Balance type equal potential shield structure.
● Fully-sealed insulation cylinder with internal excellent components.
● High accuracy and linearity, good stability and anti-interference ability.
● With good filling materials, which make the structure smaller and weight lighter, and minimize internal partial discharge.
● Small size, light weight, easy to carry in the field work.
● Inner shield anti-interference system.
● The voltage ratio can be customized, suitable for calibration.
● External voltage meter can be connected.
Technical Specifications
| Model No. | GDFR-D1-50 | GDFR-D1-100 | GDFR-D1-150 | GDFR-D1-200 | GDFR-D1-300 | GDFR-D1-400 | |
| Voltage(kV) | 50 | 100 | 150 | 200 | 300 | 400 | |
| DC frequency(Hz) | <2 | ||||||
| AC frequency(Hz) | 30-300 | ||||||
| Accuracy (G type) |
AC: 1.0%/DC: 0.5% | – | |||||
| Accuracy (H type) |
AC: 0.5%/DC: 0.5% | – | – | ||||
| Impedance (MΩ) |
650 | 1280 | 2000 | 2640 | 4000 | 5360 | |
| Capacitance (pF) |
500 | 250 | 400/160 | 300 | 200 | 300 | |
| Voltage ratio | 1000:1 or 10000:1(or customized) | ||||||
| Height (mm) | 500 | 650 | 900 | 1200 | 1750 | 2350 | |
| Dimension (mm) |
150×150 | 160×160 | 200×200 | 260×260 | 800×800 | ||
| Cable impedance(Ω) | 50 / 75 | ||||||
| Range | 1. Low range: 0-20kV 2. High range: 20kV-rated voltage |
1. Low range: 0-200kV 2. High range: 200kV-rated voltage |
|||||
| Cable length(m) | 3 | 4 | 5 | 6 | 8 | 10 | |
| Weight(kg) | 5.5 | 6.9 | 10.6 | 14.1 | 23.5 | 48.2 | |
| Packing Medium | Imported dry type high polymer materials | ||||||
| Operation temperature | 0℃-45℃ | ||||||
| Relative humidity | <85%RH, no condensation | ||||||
| Altitude | <1500m(or customized) | ||||||
| Use condition | Indoor use or outdoor use in Sunny day | ||||||
Product detail pictures:
Related Product Guide:
abide by the contract", conforms on the market requirement, joins from the market competition by its good quality likewise as provides more comprehensive and superb support for customers to let them become large winner. The pursue of the company, is definitely the clients' pleasure for China High Quality Transformer Capacitance Suppliers – High voltage divider GDFR-D1 – HV Hipot , The product will supply to all over the world, such as: Serbia, New York, New York, Satisfaction and good credit to every customer is our priority. We focus on every detail of order processing for customers till they have received safe and sound solutions with good logistics service and economical cost. Depending on this, our solutions are sold very well in the countries in Africa, the Mid-East and Southeast Asia.